Evidence map›Paper›PMID 23184741›Full record

ReviewAdvanced healthcare materials2012

Materials for diabetes therapeutics.

Kaitlin M Bratlie, Roger L York, Michael A Invernale, Robert Langer, Daniel G Anderson

Open access · greenAbstract readReview
In one paragraph

Review in Advanced healthcare materials, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 41 papers.

0numbers the graph read from it
0cells of the map it votes in
41citing papers in PubMed
9.7field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

41 citing papers in PubMed, 146 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Review
  11. Review
  12. Review
  13. Article
  14. Article
  15. Review
  16. Glucose-Responsive Microneedle Patches for Diabetes Treatment.Journal of diabetes science and technology · 2019
    Review
  17. Article
  18. Advances in bioresponsive closed-loop drug delivery systems.International journal of pharmaceutics · 2018
    Review
  19. Bioresponsive Microneedles with a Sheath Structure for HSmall (Weinheim an der Bergstrasse, Germany) · 2018
    Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Kaitlin M BratlieThe Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, 32 Vassar St., Cambridge, MA 02142, USA.
Roger L York
Michael A Invernale
Robert Langer
Daniel G Anderson
Massachusetts Institute of Technology · USVassar College · US

Funding

Understanding biocompatibility through novel in vivo imagingF32EB011580 · NIBIB · MASSACHUSETTS INSTITUTE OF TECHNOLOGY · PI BRATLIE, KAITLIN M. · 2010 to 2011
$84k
NIBIB NIH HHS F32 EB011580NIBIB NIH HHS F32-EB011580-01
6 · The paper itself

Abstract

This review is focused on the materials and methods used to fabricate closed-loop systems for type 1 diabetes therapy. Herein, we give a brief overview of current methods used for patient care and discuss two types of possible treatments and the materials used for these therapies-(i) artificial pancreases, comprised of insulin producing cells embedded in a polymeric biomaterial, and (ii) totally synthetic pancreases formulated by integrating continuous glucose monitors with controlled insulin release through degradable polymers and glucose-responsive polymer systems. Both the artificial and the completely synthetic pancreas have two major design requirements: the device must be both biocompatible and be permeable to small molecules and proteins, such as insulin. Several polymers and fabrication methods of artificial pancreases are discussed: microencapsulation, conformal coatings, and planar sheets. We also review the two components of a completely synthetic pancreas. Several types of glucose sensing systems (including materials used for electrochemical, optical, and chemical sensing platforms) are discussed, in addition to various polymer-based release systems (including ethylene-vinyl acetate, polyanhydrides, and phenylboronic acid containing hydrogels).

Indexed as

Infusion Pumps, ImplantablePancreas, ArtificialBiocompatible MaterialsDelayed-Action PreparationsDiabetes Mellitus, Type 1Equipment DesignHumansHypoglycemic AgentsInsulinBiocompatible MaterialsDelayed-Action PreparationsHypoglycemic AgentsInsulin

Identifiers

PMID23184741
PMCPMC3899887
OpenAlexW1977784332

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.