Evidence map›Paper›PMID 23183187›Full record

ArticleBiosensors & bioelectronics2013

Hot embossed polyethylene through-hole chips for bead-based microfluidic devices.

Jie Chou, Nan Du, Tina Ou, Pierre N Floriano, Nicolaos Christodoulides, John T McDevitt

Abstract read
In one paragraph

Article in Biosensors & bioelectronics, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.4field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 19 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Jie ChouDepartment of Bioengineering, Rice University, Houston, TX 77005, USA.
Nan Du
Tina Ou
Pierre N Floriano
Nicolaos Christodoulides
John T McDevitt
Rice University · US

Funding

Effects of Oral Inflammation on the Levels of Salivary Biomarkers of AMIU01DE017793 · NIDCR · UNIVERSITY OF TEXAS AT AUSTIN · PI MCDEVITT, JOHN T · 2006 to 2012
$13.0M
NIDCR NIH HHS 3U01 DE017793-02S1NIDCR NIH HHS 5U01 DE017793-2NIDCR NIH HHS U01 DE017793
6 · The paper itself

Abstract

Over the past decade, there has been a growth of interest in the translation of microfluidic systems into real-world clinical practice, especially for use in point-of-care or near patient settings. While initial fabrication advances in microfluidics involved mainly the etching of silicon and glass, the economics of scaling of these materials is not amendable for point-of-care usage where single-test applications force cost considerations to be kept low and throughput high. As such, materials base more consistent with point-of-care needs is required. In this manuscript, the fabrication of a hot embossed, through-hole low-density polyethylene ensembles derived from an anisotropically etched silicon wafer is discussed. This semi-opaque polymer that can be easily sterilized and recycled provides low background noise for fluorescence measurements and yields more affordable cost than other thermoplastics commonly used for microfluidic applications such as cyclic olefin copolymer (COC). To fabrication through-hole microchips from this alternative material for microfluidics, a fabrication technique that uses a high-temperature, high-pressure resistant mold is described. This aluminum-based epoxy mold, serving as the positive master mold for embossing, is casted over etched arrays of pyramidal pits in a silicon wafer. Methods of surface treatment of the wafer prior to casting and PDMS casting of the epoxy are discussed to preserve the silicon wafer for future use. Changes in the thickness of polyethylene are observed for varying embossing temperatures. The methodology described herein can quickly fabricate 20 disposable, single use chips in less than 30 min with the ability to scale up 4 times by using multiple molds simultaneously. When coupled as a platform supporting porous bead sensors, as in the recently developed Programmable Bio-Nano-Chip, this bead chip system can achieve limits of detection, for the cardiac biomarker C-reactive protein, of 0.3 ng/mL, thereby demonstrating that the approach is compatible with high performance, real-world clinical measurements in the context of point-of-care testing.

Indexed as

Microarray AnalysisHot TemperatureHumansMicrofluidic Analytical TechniquesMicroscopy, Electron, ScanningNanoparticlesPolyethylenePolymersSiliconPolyethylenePolymersSilicon

Identifiers

PMID23183187
PMCPMC3574225
OpenAlexW2016734668

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.