Trial reportHernia : the journal of hernias and abdominal wall surgery2014
Beneficial effects of fibrin glue (Quixil) versus Lichtenstein conventional technique in inguinal hernia repair: a randomized clinical trial.
Trial report in Hernia : the journal of hernias and abdominal wall surgery, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers, 8 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
24 citing papers in PubMed, 8 syntheses or guidelines pooled it, 48 citations in OpenAlex.
- Comparison of glue versus suture mesh fixation for primary open inguinal hernia mesh repair by Lichtenstein technique: a systematic review and meta-analysis.Hernia : the journal of hernias and abdominal wall surgery · 2022Pooled it
- Meta-analysis of postoperative pain using non-sutured or sutured single-layer open mesh repair for inguinal hernia.BJS open · 2019Pooled it
- Open Inguinal Hernia Repair: A Network Meta-analysis Comparing Self-Gripping Mesh, Suture Fixation, and Glue Fixation.World journal of surgery · 2019Pooled it
- A meta-analysis of randomized control trials assessing mesh fixation with glue versus suture in Lichtenstein inguinal hernia repair.Medicine · 2018Pooled it
- International guidelines for groin hernia management.Hernia : the journal of hernias and abdominal wall surgery · 2018Guideline
- Mesh fixation with glue versus suture for chronic pain and recurrence in Lichtenstein inguinal hernioplasty.The Cochrane database of systematic reviews · 2017Pooled it
- Uniformity of Chronic Pain Assessment after Inguinal Hernia Repair: A Critical Review of the Literature.European surgical research. Europaische chirurgische Forschung. Recherches chirurgicales europeennes · 2017Pooled it
- Update with level 1 studies of the European Hernia Society guidelines on the treatment of inguinal hernia in adult patients.Hernia : the journal of hernias and abdominal wall surgery · 2014Guideline
- One-year outcome after open inguinal hernia repair with self-fixated mesh: a randomized controlled trial.Langenbeck's archives of surgery · 2023Trial
- Postoperative pain and pain-related health-care contacts after open inguinal hernia repair with Adhesix™ and Progrip™: a randomized controlled trial.Hernia : the journal of hernias and abdominal wall surgery · 2022Trial
- A randomized clinical trial comparing early patient-reported pain after open anterior mesh repair versus totally extraperitoneal repair of inguinal hernia.The British journal of surgery · 2021Trial
- Impact of Mesh and Fixation on Chronic Inguinal Pain in Lichtenstein Hernia Repair: 5-Year Outcomes from the Finn Mesh Study.World journal of surgery · 2021Trial
- Randomized Clinical Trial Comparing Cyanoacrylate Glue Versus Suture Fixation in Lichtenstein Hernia Repair: 7-Year Outcome Analysis.World journal of surgery · 2017Trial
- Impact of different fibrin glue application methods on inguinal hernia mesh fixation capability.Scientific reports · 2024Article
- A new approach to enter Retzius space in laparoscopic transabdominal preperitoneal bilateral inguinal hernia repair.BMC surgery · 2023Article
- Longitudinal cohort study on preoperative pain as a risk factor for chronic postoperative inguinal pain after groin hernia repair at 2-year follow-up.Hernia : the journal of hernias and abdominal wall surgery · 2022Article
- Is robotic right colectomy economically sustainable? a multicentre retrospective comparative study and cost analysis.Surgical endoscopy · 2020Article
- Learning curve in open inguinal hernia repair: a quality improvement multicentre study about Lichtenstein technique.Hernia : the journal of hernias and abdominal wall surgery · 2020Article
- Mesh fixation using novel bio-adhesive coating compared to tack fixation for IPOM hernia repair: in vivo evaluation in a porcine model.Surgical endoscopy · 2019Article
- Lack of advantages of slit mesh placement during laparoscopic transabdominal preperitoneal inguinal hernia repair (TAPP): a single centre, case matched study.BMC surgery · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors at 3 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionIn inguinal hernia repair, many complications are due to mesh fixation technique. Therefore, new types of atraumatic methods of fixation have been proposed. In this article, we present the results of a prospective multicentric parallel randomized controlled trial aiming to compare two mesh fixation techniques: fibrin sealant (QUIXIL(®), Omrix Biopharmaceuticals S.A., Belgium) and Lichtenstein technique.
methodAdult patients with primary uncomplicated inguinal hernia were randomized in two groups: fibrin sealant group (FSG) and Lichtenstein group (LTG). The two groups underwent a follow-up of 15 months. Operative time is the primary outcome. Intraoperative and postoperative outcomes were analyzed. Moreover, a differential cost analysis was performed. Patients and evaluators (with exception of the surgeon who treated the patient) were blinded.
resultsA total of 102 patients, 50 in FSG and 52 in LTG, were enrolled from January 2009 to June 2010, and two patients were lost to follow-up at the twelfth month. No significant differences in baseline and clinical characteristics were observed in the two groups. Operative time was longer in LTG (median/ interquartile range: 35 min/30-42.5 min vs. 31 min/28-35 min; effect size: 0.65/95% CI 0.50-0.91; p < 0.05). No differences in intraoperative complications were observed. No significant differences were observed in early complication rate (RR = 0.62; p > 0.05). Numbness rate was lower in the FSG at 1 week (RR = 0.43; p < 0.01) and at 1 month (RR = 0.17; p < 0.05). No significant differences were observed after 6 months. Postoperative pain was lower in the FSG at 1 week (0/0-1 vs. 1/0-2; p < 0.05) and at 1 month (0/0-0 vs. 0/0-1; p < 0.05). Pain disappeared in all patients after 6 months. Analgesic assumption rate was lower in the FSG (RR = 0.42; p < 0.05). Twenty per cent of FSG and 9.62% of LTG patients were discharged within 12 h; 78% of FSG and 90.38% of LTG patients were discharged within 24 h. The only one recurrence we observed was in FSG group. About costs, although fibrin sealant needed for one mesh fixation is about 10 times more costly than the needed sutures, the total costs of the two procedures did not change significantly. This was mainly due to reduction in operative time.
conclusionsThe use of fibrin sealant determined a significant reduction in short-term numbness rate and postoperative pain. There was no relevant difference in total costs per patient between the two procedures.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.