Evidence map›Paper›PMID 23160845›Full record

ArticleBiomechanics and modeling in mechanobiology2013

Twist buckling behavior of arteries.

Justin R Garcia, Shawn D Lamm, Hai-Chao Han

Abstract read
In one paragraph

Article in Biomechanics and modeling in mechanobiology, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
1.2field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 38 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Computational simulations of the helical buckling behavior of blood vessels.International journal for numerical methods in biomedical engineering · 2019
    Article
  8. Article
  9. Article
  10. Article
  11. Effect of Axial Stretch on Lumen Collapse of Arteries.Journal of biomechanical engineering · 2016
    Article
  12. AnMaterials (Basel, Switzerland) · 2016
    Article
  13. Article
  14. Artery buckling: new phenotypes, models, and applications.Annals of biomedical engineering · 2013
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Justin R GarciaDepartment of Mechanical Engineering, Biomedical Engineering Program, University of Texas at San Antonio, UTSA-UTHSCSA, San Antonio, TX, 78249, USA.
Shawn D Lamm
Hai-Chao Han
The University of Texas Health Science Center at San Antonio · US

Funding

UTSA RISE Research Training ProgramR25GM060655 · NIGMS · UNIVERSITY OF TEXAS SAN ANTONIO · PI BAREA-RODRIGUEZ, EDWIN J · 2000 to 2022
$21.6M
PATHOBIOLOGY OF OCCLUSIVE VASCULAR DISEASET32HL007446 · NHLBI · UNIVERSITY OF TEXAS HLTH SCIENCE CENTER · PI Jean Chrisostome Bopassa · 1985 to 2026
$8.9M
Biomechanical Mechanisms of Artery TortuosityR01HL095852 · NHLBI · UNIVERSITY OF TEXAS SAN ANTONIO · PI HAN, HAI-CHAO · 2010 to 2014
$1.8M
NHLBI NIH HHS HL095852NHLBI NIH HHS R01 HL095852NHLBI NIH HHS T32 HL007446NIGMS NIH HHS GM60655NIGMS NIH HHS R25 GM060655
6 · The paper itself

Abstract

Arteries are often subjected to torsion due to body movement and surgical procedures. While it is essential that arteries remain stable and patent under twisting loads, the stability of arteries under torsion is poorly understood. The goal of this work was to experimentally investigate the buckling behavior of arteries under torsion and to determine the critical buckling torque, the critical buckling twist angle, and the buckling shape. Porcine common carotid arteries were slowly twisted in vitro until buckling occurred while subjected to a constant axial stretch ratio (1.1, 1.3, 1.5 (in vivo level) and 1.7) and lumen pressure (20, 40, 70 and 100 mmHg). Upon buckling, the arteries snapped to form a kink. For a group of six arteries, the axial stretch ratio significantly affected the critical buckling torque ([Formula: see text]) and the critical buckling twist angle ([Formula: see text]). Lumen pressure also significantly affected the critical buckling torque ([Formula: see text]) but had no significant effect on the critical twist angle ([Formula: see text]). Convex material constants for a Fung strain energy function were determined and fit well with the axial force, lumen pressure, and torque data measured pre-buckling. The material constants are valid for axial stretch ratios, lumen pressures, and rotation angles of 1.3-1.5, 20-100 mmHg, and 0-270[Formula: see text], respectively. The current study elucidates the buckling behavior of arteries under torsion and provides new insight into mechanical instability of blood vessels.

Indexed as

Torsion, MechanicalAnimalsBiomechanical PhenomenaCarotid Artery, CommonPressureRotationStress, MechanicalSus scrofaTorque

Identifiers

PMID23160845
PMCPMC3630280
OpenAlexW2055154183

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.