ArticleJournal of clinical microbiology2013
Comparative evaluation of the Nanosphere Verigene RV+ assay and the Simplexa Flu A/B & RSV kit for detection of influenza and respiratory syncytial viruses.
Article in Journal of clinical microbiology, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
24 citing papers in PubMed, 1 synthesis or guideline pooled it, 54 citations in OpenAlex.
- Multiplex PCR system for the rapid diagnosis of respiratory virus infection: systematic review and meta-analysis.Clinical microbiology and infection : the official publication of the European Society of Clinical Microbiology and Infectious Diseases · 2018Pooled it
- Review
- Clinical Performance of the AllplexTM Respiratory Panel 1 Test Compared to SimplexaTM Flu A/B and RSV for Detection of Influenza Virus and Respiratory Syncytial Virus Infection Including Their Subtyping.Medical principles and practice : international journal of the Kuwait University, Health Science Centre · 2019Article
- Performance evaluation of direct fluorescent antibody, Focus Diagnostics Simplexa™ Flu A/B & RSV and multi-parameter customized respiratory Taqman® array card in immunocompromised patients.Journal of virological methods · 2017Article
- The new frontier of diagnostics: Molecular assays and their role in infection prevention and control.American journal of infection control · 2017Review
- Comparison of NxTAG Respiratory Pathogen Panel and Anyplex II RV16 Tests for Multiplex Detection of Respiratory Pathogens in Hospitalized Children.Journal of clinical microbiology · 2016Article
- Performance Characteristics of Xpert Flu/RSV XC Assay.Journal of clinical microbiology · 2015Article
- Molecular diagnosis of respiratory viruses.Pathology · 2015Review
- Comparison of xTAG respiratory virus panel and Verigene Respiratory Virus Plus for detecting influenza virus and respiratory syncytial virus.Journal of clinical laboratory analysis · 2015Article
- Clinical utility of a near patient care microarray based diagnostic test for influenza and respiratory syncytial virus infections.International journal of clinical and experimental medicine · 2015Article
- Development and optimization of a real-time PCR assay for detection of herpes simplex and varicella-zoster viruses in skin and mucosal lesions by use of the BD Max open system.Journal of clinical microbiology · 2014Article
- Comparison of three commercial RT-PCR systems for the detection of respiratory viruses.Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology · 2014Article
- Emerging technologies for the clinical microbiology laboratory.Clinical microbiology reviews · 2014Review
- Comparison of Simplexa Flu A/B & RSV PCR with cytospin-immunofluorescence and laboratory-developed TaqMan PCR in predominantly adult hospitalized patients.Journal of clinical microbiology · 2014Article
- Infections in patients with cystic fibrosis: diagnostic microbiology update.Clinics in laboratory medicine · 2014Review
- Rapid diagnosis of influenza: state of the art.Clinics in laboratory medicine · 2014Review
- Laboratory diagnosis of viral infection.Handbook of clinical neurology · 2014Review
- Comparison of the Simplexa FluA/B & RSV direct assay and laboratory-developed real-time PCR assays for detection of respiratory virus.Journal of clinical microbiology · 2013Article
- Comparison of the FilmArray RP, Verigene RV+, and Prodesse ProFLU+/FAST+ multiplex platforms for detection of influenza viruses in clinical samples from the 2011-2012 influenza season in Belgium.Journal of clinical microbiology · 2013Article
- Molecular detection of respiratory viruses.Clinics in laboratory medicine · 2013Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Using retrospective (n = 200) and prospective (n = 150) nasopharyngeal specimens, we evaluated the Nanosphere Verigene RV+ and the Focus Diagnostics Simplexa Flu A/B & RSV tests. Overall, RV+ demonstrated sensitivities and specificities of 96.6% and 100% for influenza A virus, 100% and 99.7% for influenza B virus, and 100% and 100% for respiratory syncytial virus (RSV), while the Simplexa test sensitivities and specificities were 82.8 and 99.7%, 76.2 and 100%, and 94.6 and 100%, respectively.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.