ArticleJournal of applied clinical medical physics2012
Six degrees of freedom CBCT-based positioning for intracranial targets treated with frameless stereotactic radiosurgery.
Article in Journal of applied clinical medical physics, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 36 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
36 citing papers in PubMed, 57 citations in OpenAlex.
- Distance-adaptive geometric margins for residual rotational uncertainty in single-isocenter multitarget stereotactic radiosurgery.Physics and imaging in radiation oncology · 2026Article
- Improvement in positional accuracy with integrated surface- and X-ray imaging for intracranial stereotactic radiosurgery patients.Physics and imaging in radiation oncology · 2026Article
- Optimizing normal tissue objectives (NTO) in eclipse treatment planning system (TPS) for stereotactic treatment of multiple brain metastases using non-coplanar RapidArc and comparison with HyperArc techniques.Japanese journal of radiology · 2025Article
- The Usefulness of a Virtual Environment-Based Patient Setup Training System for Radiation Therapy.Journal of imaging · 2024Article
- Evaluation of the positional reproducibility of sedation versus non-sedation state in pediatric radiotherapy: a retrospective study.Frontiers in oncology · 2024Article
- Performance assessment of two motion management systems for frameless stereotactic radiosurgery.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2021Article
- Robustness of single-isocenter multiple-metastasis stereotactic radiosurgery end-to-end testing across institutions.Journal of radiosurgery and SBRT · 2021Article
- Geometric accuracy evaluation of a six-degree-of-freedom (6-DoF) couch with cone beam computed tomography (CBCT) using a phantom and correlation study of the position errors in pelvic tumor radiotherapy.Translational cancer research · 2020Article
- Performance of a linear accelerator couch positioning quality control task using an electronic portal imaging device.Radiological physics and technology · 2020Article
- The potential of an optical surface tracking system in non-coplanar single isocenter treatments of multiple brain metastases.Journal of applied clinical medical physics · 2020Article
- Development of twist-correction system for radiotherapy of head and neck cancer patients.Journal of applied clinical medical physics · 2019Article
- Development of a rotational set-up correction device for stereotactic head radiation therapy: A performance evaluation.Journal of applied clinical medical physics · 2019Article
- Using Smaller-Than-Standard Radiation Treatment Margins Does Not Change Survival Outcomes in Patients with High-Grade Gliomas.Practical radiation oncology · 2019Article
- Quality assurance for a six degrees-of-freedom table using a 3D printed phantom.Journal of applied clinical medical physics · 2018Article
- An evaluation of the consistency of shifts reported by three different systems for non-coplanar treatments.Journal of radiosurgery and SBRT · 2018Article
- Towards frameless maskless SRS through real-time 6DoF robotic motion compensation.Physics in medicine and biology · 2017Article
- Practical considerations of linear accelerator-based frameless extracranial radiosurgery for treatment of occipital neuralgia for nonsurgical candidates.Journal of applied clinical medical physics · 2017Article
- Comparison of Online 6 Degree-of-Freedom Image Registration of Varian TrueBeam Cone-Beam CT and BrainLab ExacTrac X-Ray for Intracranial Radiosurgery.Technology in cancer research & treatment · 2017Article
- Treatment accuracy without rotational setup corrections in intracranial SRT.Journal of applied clinical medical physics · 2016Article
- The cost-effectiveness of surgical resection and cesium-131 intraoperative brachytherapy versus surgical resection and stereotactic radiosurgery in the treatment of metastatic brain tumors.Journal of neuro-oncology · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Frameless radiosurgery is an attractive alternative to the framed procedure if it can be performed with comparable precision in a reasonable time frame. Here, we present a positioning approach for frameless radiosurgery based on in-room volumetric imaging coupled with an advanced six-degrees-of-freedom (6 DOF) image registration technique which avoids use of a bite block. Patient motion is restricted with a custom thermoplastic mask. Accurate positioning is achieved by registering a cone-beam CT to the planning CT scan and applying all translational and rotational shifts using a custom couch mount. System accuracy was initially verified on an anthropomorphic phantom. Isocenters of delineated targets in the phantom were computed and aligned by our system with an average accuracy of 0.2 mm, 0.3 mm, and 0.4 mm in the lateral, vertical, and longitudinal directions, respectively. The accuracy in the rotational directions was 0.1°, 0.2°, and 0.1° in the pitch, roll, and yaw, respectively. An additional test was performed using the phantom in which known shifts were introduced. Misalignments up to 10 mm and 3° in all directions/rotations were introduced in our phantom and recovered to an ideal alignment within 0.2 mm, 0.3 mm, and 0.4 mm in the lateral, vertical, and longitudinal directions, respectively, and within 0.3° in any rotational axis. These values are less than couch motion precision. Our first 28 patients with 38 targets treated over 63 fractions are analyzed in the patient positioning phase of the study. Mean error in the shifts predicted by the system were less than 0.5 mm in any translational direction and less than 0.3° in any rotation, as assessed by a confirmation CBCT scan. We conclude that accurate and efficient frameless radiosurgery positioning is achievable without the need for a bite block by using our 6DOF registration method. This system is inexpensive compared to a couch-based 6 DOF system, improves patient comfort compared to systems that utilize a bite block, and is ideal for the treatment of pediatric patients with or without general anesthesia, as well as of patients with dental issues. From this study, it is clear that only adjusting for 4 DOF may, in some cases, lead to significant compromise in PTV coverage. Since performing the additional match with 6 DOF in our registration system only adds a relatively short amount of time to the overall process, we advocate making the precise match in all cases.