ArticleJournal of applied clinical medical physics2012

Six degrees of freedom CBCT-based positioning for intracranial targets treated with frameless stereotactic radiosurgery.

Anees Dhabaan, Eduard Schreibmann, Arsalan Siddiqi, Eric Elder, Tim Fox, Tomi Ogunleye, Natia Esiashvili, Walter Curran, Ian Crocker, Hui-Kuo Shu

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 36 papers.

0numbers the graph read from it
0cells of the map it votes in
36citing papers in PubMed
7.2field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

36 citing papers in PubMed, 57 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Performance assessment of two motion management systems for frameless stereotactic radiosurgery.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2021
    Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Treatment accuracy without rotational setup corrections in intracranial SRT.Journal of applied clinical medical physics · 2016
    Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 1 country.

Anees DhabaanDepartment of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA, USA. anees.dhabaan@emory.edu
Eduard Schreibmann
Arsalan Siddiqi
Eric Elder
Tim Fox
Tomi Ogunleye
Natia Esiashvili
Walter Curran
Ian Crocker
Hui-Kuo Shu
Emory University · USPiedmont Cancer Institute · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Frameless radiosurgery is an attractive alternative to the framed procedure if it can be performed with comparable precision in a reasonable time frame. Here, we present a positioning approach for frameless radiosurgery based on in-room volumetric imaging coupled with an advanced six-degrees-of-freedom (6 DOF) image registration technique which avoids use of a bite block. Patient motion is restricted with a custom thermoplastic mask. Accurate positioning is achieved by registering a cone-beam CT to the planning CT scan and applying all translational and rotational shifts using a custom couch mount. System accuracy was initially verified on an anthropomorphic phantom. Isocenters of delineated targets in the phantom were computed and aligned by our system with an average accuracy of 0.2 mm, 0.3 mm, and 0.4 mm in the lateral, vertical, and longitudinal directions, respectively. The accuracy in the rotational directions was 0.1°, 0.2°, and 0.1° in the pitch, roll, and yaw, respectively. An additional test was performed using the phantom in which known shifts were introduced. Misalignments up to 10 mm and 3° in all directions/rotations were introduced in our phantom and recovered to an ideal alignment within 0.2 mm, 0.3 mm, and 0.4 mm in the lateral, vertical, and longitudinal directions, respectively, and within 0.3° in any rotational axis. These values are less than couch motion precision. Our first 28 patients with 38 targets treated over 63 fractions are analyzed in the patient positioning phase of the study. Mean error in the shifts predicted by the system were less than 0.5 mm in any translational direction and less than 0.3° in any rotation, as assessed by a confirmation CBCT scan. We conclude that accurate and efficient frameless radiosurgery positioning is achievable without the need for a bite block by using our 6DOF registration method. This system is inexpensive compared to a couch-based 6 DOF system, improves patient comfort compared to systems that utilize a bite block, and is ideal for the treatment of pediatric patients with or without general anesthesia, as well as of patients with dental issues. From this study, it is clear that only adjusting for 4 DOF may, in some cases, lead to significant compromise in PTV coverage. Since performing the additional match with 6 DOF in our registration system only adds a relatively short amount of time to the overall process, we advocate making the precise match in all cases.

Indexed as

Radiotherapy Planning, Computer-AssistedBrain NeoplasmsChildCone-Beam Computed TomographyHumansImmobilizationMovementPatient PositioningPhantoms, ImagingRadiosurgeryRadiotherapy Setup ErrorsRetrospective Studies

Identifiers

PMID23149782
PMCPMC5718543
OpenAlexW2127246634

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.