Evidence map›Paper›PMID 23103694›Full record

ArticleASAIO journal (American Society for Artificial Internal Organs : 1992)

Design and in vitro assessment of an improved, low-resistance compliant thoracic artificial lung.

Rebecca E Schewe, Khalil M Khanafer, Aarthi Arab, Jeffrey A Mitchell, David J Skoog, Keith E Cook

Abstract read
In one paragraph

Article in ASAIO journal (American Society for Artificial Internal Organs : 1992). The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed.

  1. Review
  2. Bioengineering Progress in Lung Assist Devices.Bioengineering (Basel, Switzerland) · 2021
    Review
  3. Article
  4. Review
  5. Low-Resistance, Concentric-Gated Pediatric Artificial Lung for End-Stage Lung Failure.ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2020
    Article
  6. In Vivo 5 Day Animal Studies of a Compact, Wearable Pumping Artificial Lung.ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2019
    Article
  7. Early in vivo experience with the pediatric continuous-flow total artificial heart.The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation · 2018
    Article
  8. In vitro and in vivo evaluation of a novel integrated wearable artificial lung.The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation · 2017
    Article
  9. Article
  10. Fourteen Day In Vivo Testing of a Compliant Thoracic Artificial Lung.ASAIO journal (American Society for Artificial Internal Organs : 1992)
    Article
  11. Fiber Bundle Design for an Integrated Wearable Artificial Lung.ASAIO journal (American Society for Artificial Internal Organs : 1992)
    Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Rebecca E ScheweDepartment of Biomedical Engineering, University of Michigan, Ann Arbor, USA.
Khalil M Khanafer
Aarthi Arab
Jeffrey A Mitchell
David J Skoog
Keith E Cook

Funding

Compliant Thoracic Artificial LungsR01HL089043 · NHLBI · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI COOK, KEITH E · 2009 to 2017
$4.2M
NHLBI NIH HHS R01 HL089043NHLBI NIH HHS R01HL089043
6 · The paper itself

Abstract

Current thoracic artificial lungs (TALs) have blood flow impedances greater than the natural lungs, which can result in abnormal pulmonary hemodynamics. This study investigated the impedance and gas transfer performance of a compliant TAL (cTAL). Fluid-structure interaction analysis was performed using ADINA (ADINA R&D Inc., Watertown, MA) to examine the effect of the inlet and outlet expansion angle, θ, on device impedance and blood flow patterns. Based on the results, the θ = 45° model was chosen for prototyping and in vitro testing. Glycerol was pumped through this cTAL at 2, 4, and 6 L/min at 80 and 100 beats/min, and the zeroth and first harmonic impedance moduli, Z(0) and Z(1), were calculated. Gas transfer testing was conducted at blood flow rates of 3, 5, and 7 L/min. Fluid-structure interaction results indicated that the 45° model had an ideal combination of low impedance and even blood flow patterns and was thus chosen for prototyping. In vitro, Z(0) = 0.53 ± 0.06 mm Hg/(L/min) and Z(1) = 0.86 ± 0.08 mm Hg/(L/min) at 4 L/min and 100 beats/min. Outlet PO(2) and SO(2) values were above 200 mm Hg and 99.5%, respectively, at each flow rate. Thus, the cTAL had lower impedance than hard shell TALs and excellent gas transfer.

Indexed as

Artificial OrgansElectric ImpedanceHemodynamicsHumansLungLung CompliancePulmonary Gas Exchange

Identifiers

PMID23103694
PMCPMC3538888

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.