ArticleIEEE transactions on medical imaging2013
Correction for collimator-detector response in SPECT using point spread function template.
Article in IEEE transactions on medical imaging, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
24 citing papers in PubMed, 54 citations in OpenAlex.
- Patient specific, imaging-informed modeling of rhenium-186 nanoliposome delivery via convection-enhanced delivery in glioblastoma multiforme.Biomedical physics & engineering express · 2021Trial
- Back-table specimen scanning using gantry-free hybrid hSPECT/LiDAR imaging: a feasibility study during PSMA-radioguided surgery.Surgical endoscopy · 2025Article
- A review of state-of-the-art resolution improvement techniques in SPECT imaging.EJNMMI physics · 2025Review
- Characterization of accurate 3D collimator-detector response function for single- and multi-lofthole collimated SPECT cameras.Japanese journal of radiology · 2024Article
- Image-guided patient-specific optimization of catheter placement for convection-enhanced nanoparticle delivery in recurrent glioblastoma.Computers in biology and medicine · 2024Article
- From SPECT/CT towards absolute quantification? - the case of unilateral condylar hyperplasia of the mandible.EJNMMI physics · 2024Article
- Resolution recovery on list mode MLEM reconstruction for dynamic cardiac SPECT system.Biomedical physics & engineering express · 2023Article
- In silico simulation of hepatic arteries: An open-source algorithm for efficient synthetic data generation.Medical physics · 2023Article
- Validation ofEJNMMI physics · 2023Article
- Biodistribution and dosimetry for combined [European journal of nuclear medicine and molecular imaging · 2023Article
- Comparison ofPhysica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2021Article
- Collimator and Energy Window Evaluation in Ga-67 Imaging by Monte Carlo SimulationMolecular imaging and radionuclide therapy · 2020Article
- Algorithms and Analyses for Joint Spectral Image Reconstruction in Y-90 Bremsstrahlung SPECT.IEEE transactions on medical imaging · 2020Article
- Image quality characteristics of myocardial perfusion SPECT imaging using state-of-the-art commercial software algorithms: evaluation of 10 reconstruction methods.American journal of nuclear medicine and molecular imaging · 2020Article
- Fast quantitative reconstruction with focusing collimators for liver SPECT.EJNMMI physics · 2018Article
- Review
- Penalized-Likelihood Reconstruction With High-Fidelity Measurement Models for High-Resolution Cone-Beam Imaging.IEEE transactions on medical imaging · 2018Article
- Application of the 4-D XCAT Phantoms in Biomedical Imaging and Beyond.IEEE transactions on medical imaging · 2018Review
- Improved quantitativeMedical physics · 2017Article
- The Use of Anatomical Information for Molecular Image Reconstruction Algorithms: Attenuation/Scatter Correction, Motion Compensation, and Noise Reduction.Nuclear medicine and molecular imaging · 2016Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 2 institutions in 1 country.
Funding
Abstract
Compensating for the collimator-detector response (CDR) in SPECT is important for accurate quantification. The CDR consists of both a geometric response and a septal penetration and collimator scatter response. The geometric response can be modeled analytically and is often used for modeling the whole CDR if the geometric response dominates. However, for radionuclides that emit medium or high-energy photons such as I-131, the septal penetration and collimator scatter response is significant and its modeling in the CDR correction is important for accurate quantification. There are two main methods for modeling the depth-dependent CDR so as to include both the geometric response and the septal penetration and collimator scatter response. One is to fit a Gaussian plus exponential function that is rotationally invariant to the measured point source response at several source-detector distances. However, a rotationally-invariant exponential function cannot represent the star-shaped septal penetration tails in detail. Another is to perform Monte-Carlo (MC) simulations to generate the depth-dependent point spread functions (PSFs) for all necessary distances. However, MC simulations, which require careful modeling of the SPECT detector components, can be challenging and accurate results may not be available for all of the different SPECT scanners in clinics. In this paper, we propose an alternative approach to CDR modeling. We use a Gaussian function plus a 2-D B-spline PSF template and fit the model to measurements of an I-131 point source at several distances. The proposed PSF-template-based approach is nearly non-parametric, captures the characteristics of the septal penetration tails, and minimizes the difference between the fitted and measured CDR at the distances of interest. The new model is applied to I-131 SPECT reconstructions of experimental phantom measurements, a patient study, and a MC patient simulation study employing the XCAT phantom. The proposed model yields up to a 16.5 and 10.8% higher recovery coefficient compared to the results with the conventional Gaussian model and the Gaussian plus exponential model, respectively.