Evidence map›Paper›PMID 23077449›Full record

ArticleRadiology and oncology2012

The optimization of needle electrode number and placement for irreversible electroporation of hepatocellular carcinoma.

Oyinlolu O Adeyanju, Haitham M Al-Angari, Alan V Sahakian

Open access · goldAbstract read
In one paragraph

Article in Radiology and oncology, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed
3.0field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed, 49 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. [Ablative therapy of small renal masses].Der Urologe. Ausg. A · 2018
    Review
  8. Article
  9. Article
  10. Review
  11. Article
  12. Article
  13. Review
  14. Article
  15. Tumor ablation: common modalities and general practices.Techniques in vascular and interventional radiology · 2013
    Review
  16. Article
  17. Article
  18. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Oyinlolu O Adeyanju
Haitham M Al-Angari
Alan V Sahakian
Northwestern University · US

Funding

MRI for In Vivo Quantification of Yttrium-90 Microsphere BiodistributionF31CA150658 · NCI · NORTHWESTERN UNIVERSITY AT CHICAGO · PI ADEYANJU, OYINLOLU · 2010 to 2011
$62k
NCI NIH HHS F31 CA150658
6 · The paper itself

Abstract

backgroundIrreversible electroporation (IRE) is a novel ablation tool that uses brief high-voltage pulses to treat cancer. The efficacy of the therapy depends upon the distribution of the electric field, which in turn depends upon the configuration of electrodes used.

methodsWe sought to optimize the electrode configuration in terms of the distance between electrodes, the depth of electrode insertion, and the number of electrodes. We employed a 3D Finite Element Model and systematically varied the distance between the electrodes and the depth of electrode insertion, monitoring the lowest voltage sufficient to ablate the tumor, V(IRE). We also measured the amount of normal (non-cancerous) tissue ablated. Measurements were performed for two electrodes, three electrodes, and four electrodes. The optimal electrode configuration was determined to be the one with the lowest V(IRE), as that minimized damage to normal tissue.

resultsThe optimal electrode configuration to ablate a 2.5 cm spheroidal tumor used two electrodes with a distance of 2 cm between the electrodes and a depth of insertion of 1 cm below the halfway point in the spherical tumor, as measured from the bottom of the electrode. This produced a V(IRE) of 3700 V. We found that it was generally best to have a small distance between the electrodes and for the center of the electrodes to be inserted at a depth equal to or deeper than the center of the tumor. We also found the distance between electrodes was far more important in influencing the outcome measures when compared with the depth of electrode insertion.

conclusionsOverall, the distribution of electric field is highly dependent upon the electrode configuration, but the optimal configuration can be determined using numerical modeling. Our findings can help guide the clinical application of IRE as well as the selection of the best optimization algorithm to use in finding the optimal electrode configuration.

Indexed as

hepatocellular carcinomairreversible electroporationoptimization, electrode configuration

Identifiers

PMID23077449
PMCPMC3472940
OpenAlexW2031338364

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked