Evidence map›Paper›PMID 23076923›Full record

SynthesisThe Cochrane database of systematic reviews2012

Interventions to prevent occupational noise-induced hearing loss.

Jos H Verbeek, Erik Kateman, Thais C Morata, Wouter A Dreschler, Christina Mischke

Abstract readMeta-AnalysisSystematic Review
PubMed Publisher
In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 28 papers, 4 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
28citing papers in PubMed, 4 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

28 citing papers in PubMed, 4 syntheses or guidelines pooled it, 68 citations in OpenAlex.

  1. Interventions for prevention of bullying in the workplace.The Cochrane database of systematic reviews · 2017
    Pooled it
  2. Occupational noise exposure and hearing: a systematic review.International archives of occupational and environmental health · 2016
    Pooled it
  3. Pooled it
  4. Pooled it
  5. Article
  6. Article
  7. Prevalence of hearing loss and influencing factors among workers in Wuhan, China.Environmental science and pollution research international · 2021
    Article
  8. Metrics to assess injury prevention programs for young workers in high-risk occupations: a scoping review of the literature.Health promotion and chronic disease prevention in Canada : research, policy and practice · 2018
    Article
  9. Article
  10. Current insights in noise-induced hearing loss: a literature review of the underlying mechanism, pathophysiology, asymmetry, and management options.Journal of otolaryngology - head & neck surgery = Le Journal d'oto-rhino-laryngologie et de chirurgie cervico-faciale · 2017
    Review
  11. Occupational noise exposure, psychosocial working conditions and the risk of tinnitus.International archives of occupational and environmental health · 2017
    Article
  12. Article
  13. Article
  14. A Scan of CDC-Authored Articles on Legal Epidemiology, 2011-2015.Public health reports (Washington, D.C. : 1974) · 2016
    Article
  15. Article
  16. Article
  17. Article
  18. Review
  19. Adenosine amine congener as a cochlear rescue agent.BioMed research international · 2014
    Article
  20. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 3 countries.

Jos H VerbeekCochrane Occupational Safety and Health Review Group, Finnish Institute of Occupational Health, Kuopio, Finland.jos.verbeek@ttl.fi.
Erik Kateman
Thais C Morata
Wouter A Dreschler
Christina Mischke
Finnish Institute of Occupational Health · FIAcademic Medical Center · NLNational Institute for Occupational Safety and Health · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMillions of workers worldwide are exposed to noise levels that increase their risk of hearing impairment. Little is known about the effectiveness of hearing loss prevention interventions.

objectivesTo assess the effectiveness of non-pharmaceutical interventions for preventing occupational noise exposure or occupational hearing loss compared to no intervention or alternative interventions. SEARCH

methodsWe searched the Cochrane Central Register of Controlled Trials (CENTRAL); PubMed; EMBASE; CINAHL; Web of Science; BIOSIS Previews; Cambridge Scientific Abstracts; and OSH update to 25 January 2012. SELECTION CRITERIA: We included randomised controlled trials (RCT), controlled before-after studies (CBA) and interrupted time-series (ITS) of non-clinical hearing loss prevention interventions under field conditions among workers exposed to noise. DATA COLLECTION AND ANALYSIS: Two authors independently assessed study eligibility and risk of bias and extracted data. MAIN

resultsWe included 25 studies. We found no controlled studies on engineering controls for noise exposure but one study evaluated legislation to reduce noise exposure in a 12-year time-series analysis. Eight studies with 3,430 participants evaluated immediate and long-term effects of personal hearing protection devices (HPDs) and sixteen studies with 82,794 participants evaluated short and long-term effects of hearing loss prevention programmes (HLPPs). The overall quality of studies was low to very low.The one ITS study that evaluated the effect of new legislation in reducing noise exposure found that the median noise level decreased by 27.7 dB(A) (95% confidence interval (CI) -36.1 to -19.3 dB) immediately after the implementation of stricter legislation and that this was associated with a favourable downward trend in time of -2.1 dB per year (95% CI -4.9 to 0.7).Hearing protection devices attenuated noise with about 20 dB(A) with variation among brands and types but for ear plugs these findings depended almost completely on proper instruction of insertion. Noise attenuation ratings of hearing protection under field conditions were consistently lower than the ratings provided by the manufacturers.One cluster-RCT compared a three-year information campaign as part of a hearing loss prevention programme for agricultural students to audiometry only with three and 16-year follow-up but there were no significant differences in hearing loss. Another study compared a HLPP, which provided regular personal noise exposure information, to a programme without this information in a CBA design. Exposure information was associated with a favourable but non-significant reduction of the rate of hearing loss of -0.82 dB per year (95% CI -1.86 to 0.22). Another cluster-RCT evaluated the effect of extensive on-site training sessions and the use of personal noise-level indicators versus information only on noise levels but did not find a significant difference after four months follow-up (Mean Difference (MD) -0.30 dB(A) (95%CI -3.95 to 3.35).There was very low quality evidence in four very long-term studies, that better use of HPDs as part of a HLPP decreased the risk of hearing loss compared to less well used hearing protection in HLPPs. Other aspects of the HLPP such as training and education of workers or engineering controls did not show a similar effect.In four long-term studies, workers in a HLPP still had a 0.5 dB greater hearing loss at 4 kHz than workers that were not exposed to noise (95% CI -0.5 to 1.7) which is about the level of hearing loss caused by exposure to 85 dB(A). In addition, two other studies showed substantial risk of hearing loss in spite of the protection of a HLPP compared to non-exposed workers. AUTHORS'

conclusionsThere is low quality evidence that implementation of stricter legislation can reduce noise levels in workplaces. Even though case studies show that substantial reductions in noise levels in the workplace can be achieved, there are no controlled studies of the effectiveness of such measures. The effectiveness of hearing protection devices depends on training and their proper use. There is very low quality evidence that the better use of hearing protection devices as part of HLPPs reduces the risk of hearing loss, whereas for other programme components of HLPPs we did not find such an effect. Better implementation and reinforcement of HLPPs is needed. Better evaluations of technical interventions and long-term effects are needed.

Indexed as

Ear Protective DevicesHealth EducationHearing Loss, Noise-InducedHumansNoise, OccupationalOccupational DiseasesProgram EvaluationRandomized Controlled Trials as Topic

Identifiers

PMID23076923
OpenAlexW4253490290

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.