Evidence map›Paper›PMID 23074250›Full record

ArticleProceedings of the National Academy of Sciences of the United States of America2012

Emphysema diagnosis using X-ray dark-field imaging at a laser-driven compact synchrotron light source.

Simone Schleede, Felix G Meinel, Martin Bech, Julia Herzen, Klaus Achterhold, Guillaume Potdevin, Andreas Malecki, Silvia Adam-Neumair, Sven F Thieme, Fabian Bamberg and 9 more

Open access · greenAbstract read
In one paragraph

Article in Proceedings of the National Academy of Sciences of the United States of America, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 62 papers.

0numbers the graph read from it
0cells of the map it votes in
62citing papers in PubMed
21.3field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

62 citing papers in PubMed, 189 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Edge-Illumination X-Ray Dark-Field Tomography.Physical review applied · 2023
    Article
  10. Article
  11. Article
  12. Review
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. High-resolution multicontrast tomography with an X-ray microarray anode-structured target source.Proceedings of the National Academy of Sciences of the United States of America · 2021
    Article
  20. Article

2 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

19 authors at 5 institutions in 3 countries.

Simone SchleedeDepartment of Physics and Institute of Medical Engineering, Technische Universität München, 85748 Garching, Germany. schleede@tum.de
Felix G Meinel
Martin Bech
Julia Herzen
Klaus Achterhold
Guillaume Potdevin
Andreas Malecki
Silvia Adam-Neumair
Sven F Thieme
Fabian Bamberg
Konstantin Nikolaou
Alexander Bohla
Ali Ö Yildirim
Roderick Loewen
Martin Gifford
Ronald Ruth
Oliver Eickelberg
Maximilian Reiser
Franz Pfeiffer
Technical University of Munich · DELudwig-Maximilians-Universität München · DEHelmholtz Zentrum München · DELyncean Technologies (United States) · USSLAC National Accelerator Laboratory · US

Funding

Compact X-ray Station for Protein CrystallographyR44GM074437 · NIGMS · LYNCEAN TECHNOLOGIES, INC. · PI LOEWEN, RODERICK J · 2005 to 2009
$9.3M
A Clinical High Resolution Imaging System (CHRIS)R43RR025730 · NCRR · LYNCEAN TECHNOLOGIES, INC. · PI LOEWEN, RODERICK J · 2009 to 2009
$1.3M
NCRR NIH HHS R43 RR025730NCRR NIH HHS R43-RR025730NIGMS NIH HHS R44 GM074437NIGMS NIH HHS R44-GM074437
6 · The paper itself

Abstract

In early stages of various pulmonary diseases, such as emphysema and fibrosis, the change in X-ray attenuation is not detectable with absorption-based radiography. To monitor the morphological changes that the alveoli network undergoes in the progression of these diseases, we propose using the dark-field signal, which is related to small-angle scattering in the sample. Combined with the absorption-based image, the dark-field signal enables better discrimination between healthy and emphysematous lung tissue in a mouse model. All measurements have been performed at 36 keV using a monochromatic laser-driven miniature synchrotron X-ray source (Compact Light Source). In this paper we present grating-based dark-field images of emphysematous vs. healthy lung tissue, where the strong dependence of the dark-field signal on mean alveolar size leads to improved diagnosis of emphysema in lung radiographs.

Indexed as

LasersSynchrotronsAnimalsEmphysemaFemaleMiceMice, Inbred C57BLX-Rays

Identifiers

PMID23074250
PMCPMC3497797
OpenAlexW2168366932

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.