Evidence map›Paper›PMID 23070906›Full record

ArticleMolecular biology reports2012

Development of a broad-spectrum fluorescent heavy metal bacterial biosensor.

P Gireesh-Babu, Aparna Chaudhari

Abstract read
PubMed Publisher
In one paragraph

Article in Molecular biology reports, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Review
  5. Review
  6. Review
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

P Gireesh-BabuDivision of Fish Genetics and Biotechnology, Central Institute of Fisheries Education, Versova, Mumbai, 400 061, India. girishbiotech@gmail.com
Aparna Chaudhari

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Bacterial biosensors can measure pollution in terms of their actual toxicity to living organisms. A recombinant bacterial biosensor has been constructed that is known to respond to toxic levels of Zn(2+), Cd(2+) and Hg(2+). The zinc regulatory gene zntR and zntA promoter from znt operon of E. coli have been used to trigger the expression of GFP reporter protein at toxic levels of these ions. The sensor was induced with 3-800 ppm of Zn(2+), 0.005-4 ppm of Cd(2+) and 0.001-0.12 ppm of Hg(2+) ions. Induction studies were also performed in liquid media to quantify GFP fluorescence using fluorimeter. To determine the optimum culture conditions three different incubation periods (16, 20 and 24 h) were followed. Results showed an increased and consistent fluorescence in cells incubated for 16 h. Maximum induction for Zn(2+), Cd(2+) and Hg(2+) was observed at 20, 0.005 and 0.002 ppm, respectively. The pPROBE-zntR-zntA biosensor reported here can be employed as a primary screening technique for aquatic heavy metal pollution.

Indexed as

Biosensing TechniquesCadmiumEscherichia coliFluorescenceMercuryMetals, HeavyTime FactorsZincCadmiumMercuryMetals, HeavyZinc

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.