Evidence map›Paper›PMID 23067266›Full record

ArticleJournal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance2012

The protein binding substance ibuprofen does not affect the T1 time or partition coefficient in contrast-enhanced cardiovascular magnetic resonance.

Nadine Kawel, Francesco Santini, Tanja Haas, Johannes M Froehlich, Jens Bremerich

Open access · goldAbstract read
In one paragraph

Article in Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.7field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 5 citations in OpenAlex.

  1. Review of Journal of Cardiovascular Magnetic Resonance 2013.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2014
    Review
  2. Review of Journal of Cardiovascular Magnetic Resonance 2012.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2013
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Nadine KawelDepartment of Radiology, University Hospital Basel, Basel, Switzerland. nadine.kawel@gmx.de
Francesco Santini
Tanja Haas
Johannes M Froehlich
Jens Bremerich
University Hospital of Basel · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundContrast enhanced cardiovascular magnetic resonance (CMR) with T1 mapping enables quantification of diffuse myocardial fibrosis. Various factors, however, can interfere with T1 measurements. The purpose of the current study was to assess the effect of co-medication with a typical protein binding drug (ibuprofen) on T1 values in vitro and in vivo.

methods50 vials were prepared with different concentrations of gadobenate dimeglumine, ibuprofen and human serum albumin in physiologic NaCl solution and imaged at 1.5T with a spin echo sequence at multiple TRs to measure T1 values and calculate relaxivities. 10 volunteers (5 men; 31 ± 6.3 years) were imaged at 1.5T. T1 values for myocardium and blood pool were determined for various time points after administration of 0.15 mmol/kg gadobenate dimeglumine using a modified look-locker inversion-recovery sequence before and after administration of ibuprofen over 24 hours. The partition coefficient was calculated as ΔR1myocardium/ΔR1blood, where R1=1/T1.

resultsIn vitro no significant correlation was found between relaxivity and ibuprofen concentration, neither in absence (r=-0.15, p=0.40) nor in presence of albumin (r=-0.32, p=0.30). In vivo there was no significant difference in post contrast T1 times of myocardium and blood, respectively and also in the partition coefficient between exam 1 and 2 (p>0.05). There was good agreement of the T1 times of myocardium and blood and the partition coefficient, respectively between exam 1 and 2.

conclusionsContrast enhanced T1 mapping is unaffected by co-medication with the protein binding substance ibuprofen and has an excellent reproducibility.

Indexed as

Magnetic Resonance ImagingAdultContrast MediaFemaleHeartHumansIbuprofenImage EnhancementInjections, IntravenousLinear ModelsMaleMeglumineMyocardiumOrganometallic CompoundsPredictive Value of TestsProtein BindingALB protein, humanContrast Mediagadobenic acidIbuprofenMeglumineOrganometallic CompoundsSerum AlbuminSerum Albumin, Human

Identifiers

PMID23067266
PMCPMC3500644
OpenAlexW2119285922

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.