ArticlePathology oncology research : POR2013
Radioguided occult lesion localisation versus wire-guided lumpectomy in the treatment of non-palpable breast lesions.
Article in Pathology oncology research : POR, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 32 citations in OpenAlex.
- [The evolution of surgical management for early-stage breast cancer at a university breast centre in Hungary].Magyar onkologia · 2026Article
- Global research trends and thematic evolution of imaging-guided localization in breast cancer surgery: a bibliometric analysis.Gland surgery · 2026Article
- Utilize in-vivo offline PET/CT imaging to evaluate range deviations of implanted metal-clips in whole-breast proton radiotherapy.Journal of radiation research · 2025Article
- [Use of imaging methods in the current screening, diagnostics and treatment of breast cancer - Professional guidelines. 5th Breast Cancer Consensus Meeting (2025)].Magyar onkologia · 2025Article
- [Modern surgical treatment of breast cancer. 5th Breast Cancer Consensus Conference].Magyar onkologia · 2025Article
- Comparison of wire-guided localization (WGL) and radio-guided occult lesion localization (ROLL) in localization of non-palpable breast lesions.World journal of surgical oncology · 2023Article
- Ultrasound-guided hookwire localization of non palpable cervical lymphadenopathy: A case-control study of operative time.Cancer medicine · 2023Article
- Modern Breast Cancer Surgery 1st Central-Eastern European Professional Consensus Statement on Breast Cancer.Pathology oncology research : POR · 2022Article
- Use of Diagnostic Imaging Modalities in Modern Screening, Diagnostics and Management of Breast Tumours 1st Central-Eastern European Professional Consensus Statement on Breast Cancer.Pathology oncology research : POR · 2022Review
- Assessment of Ultrasound / Radio-guided Occult Lesion Localization in Non-palpable Breast Lesions.Asia Oceania journal of nuclear medicine & biology · 2018Article
- Predictive Factors for Positive Margin and the Surgical Learning Curve in Non-Palpable Breast Cancer After Wire-Guided Localization - Prospective Study of 214 Consecutive Patients.Pathology oncology research : POR · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The purpose of this study was to compare the two methods-guidewire localisation and the radioguided occult lesion localisation-used in the localisation and surgical removal of non-palpable breast tumours. This retrospective study enrolled patients diagnosed with nonpalpable malignant breast tumours. In this study either guidewire localisation (GWL, n = 69) or radioguided occult lesion localisation (ROLL, n = 321) was used for the detection and removal of the tumours. The two methods were compared with regards to preoperative localisation time, operating time, removed specimen volume, the pathological tumour size, the presence of positive surgical margins and postoperative complications. Furthermore, we have also investigated other factors that could have an impact on the frequency of positive resection margins. The localisation time was significantly shorter in the ROLL group, both with ultrasound guidance (5.7 ± 1.44 min vs. 21.6 ± 2.37 min, p = 0.05) and with radiographic guidance (21.8 ± 3.1 min vs. 41.6 ± 3.75 min, p = 0.021) as well. No significant difference was observed between the two methods in terms of operating time, removed specimen volume and pathological tumour size, or the presence of positive resection margins, or the occurrence of postoperative wound infections. The size of the tumour (ROLL, GWL grps), the presence of a multifocal tumour (ROLL grp), the presence of an extensive in situ breast carcinoma around the invasive cancer (ROLL, GWL grps) and the volume of the removed breast specimen (GWL grp) significantly increased the frequency of positive resection margins. We recommend the use of the ROLL method for the removal of nonpalpable breast tumours as it has a much shorter localisation time, and it is a simpler surgical technique as well.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.