Evidence map›Paper›PMID 23064805›Full record

ReviewOral and maxillofacial surgery2013

Fixation of mandibular angle fractures: in vitro biomechanical assessments and computer-based studies.

Bruno Ramos Chrcanovic

Abstract readReview
PubMed Publisher
In one paragraph

Review in Oral and maxillofacial surgery, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed.

  1. Trial
  2. Trial
  3. Article
  4. Article
  5. Article
  6. Royal Society open science · 2022
    Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Bruno Ramos ChrcanovicDepartment of Prosthodontics, Faculty of Odontology, Malmö University, 205 06, Malmö, Sweden, brunochrcanovic@hotmail.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe purpose of this study was to review the literature regarding the evolution of current thoughts on fixation of mandibular angle fractures (MAFs), based on in vitro biomechanical assessments and computer-based studies.

methodsAn electronic search in PubMed was undertaken in August 2012. The titles and abstracts from these results were read to identify studies within the selection criteria. Eligibility criteria included studies from the last 30 years (from 1983 onwards).

resultsThe search strategy initially identified 767 studies. Thirty-one studies were identified without repetition within the selection criteria. Two articles showing significance in the development of treatment techniques was included. Additional hand searching yielded five additional papers. Thus, a total of 38 studies were included.

conclusionsThe osteosynthesis positions as well as the plating technique play important roles in the stability of MAF repair. The only in vitro study evaluating the use of wire osteosynthesis concluded that wires placed through the lower border approach would provide greater stability than those at the upper border. Many studies indicate that the use of two miniplates avoids (or decreases) lateral displacement of the lower mandibular border and opening of the inferior fracture gap. Some studies even suggest that the use of two miniplates may be considered a more "rigid" fixation technique for MAFs than the use of a reconstruction plate. When using two miniplates, the biplanar plate orientation provides greater biomechanical stability than the monoplanar one. However, despite its greater biomechanical stability, the two-miniplate technique has some disadvantages that should also be taken into account. Studies with biodegradable plates suggest the use of at least two plates for each MAF. There are few studies with compression plates, and they have not yet reached a consensus. The solitary lag screw proved to withstand the functional loading of the mandible; however, only few biomechanical assessments were performed. In vitro studies have shown good biomechanical stability with the use of 3-D grid plates. The use of malleable miniplates alone is not sufficient to withstand the early postoperative bite force. Some studies suggest that the segment of the tension band miniplate located at the distal fragment of the MAF should be fixed with three screws. The studies also showed some limitations. None considered the stabilization of the fracture site afforded by the masseter-pterygoid muscle pouch. Most of the studies did not evaluate plating system strength in the long term and therefore did not observe the effect of resorption on the strength of the different biodegradable plating systems. Another limitation of many studies is the absence of a control group. A confounding factor that could not be tested in in vitro investigations is the additional resistance to displacement of jagged fracture margins present in the human fracture.

Indexed as

Finite Element AnalysisBiomechanical PhenomenaBite ForceBone PlatesBone ScrewsFracture Fixation, InternalHumansImaging, Three-DimensionalIn Vitro TechniquesMandibular FracturesMandibular Reconstruction

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.