Evidence map›Paper›PMID 23063044›Full record

ArticleJournal of diabetes science and technology2012

GlucoMen Day continuous glucose monitoring system: a screening for enzymatic and electrochemical interferents.

Fausto Lucarelli, Francesco Ricci, Felice Caprio, Francesco Valgimigli, Cosimo Scuffi, Danila Moscone, Giuseppe Palleschi

Open access · bronzeAbstract readEvaluation Study
In one paragraph

Article in Journal of diabetes science and technology, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed
2.0field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed, 40 citations in OpenAlex.

  1. Review
  2. Review
  3. Review
  4. Article
  5. Review
  6. Article
  7. Semi-Implantable Bioelectronics.Nano-micro letters · 2022
    Review
  8. Article
  9. Review
  10. Review
  11. Review
  12. Article
  13. Article
  14. Article
  15. Review
  16. Article
  17. Review
  18. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Fausto LucarelliScientific and Technology Affairs, A. Menarini Diagnostics, Florence, Italy. flucarelli@menarini.it
Francesco Ricci
Felice Caprio
Francesco Valgimigli
Cosimo Scuffi
Danila Moscone
Giuseppe Palleschi
University of Rome Tor Vergata · ITMenarini Group (Italy) · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundWhile most of the common drugs with the potential to interfere with continuous glucose monitoring (CGM) systems are accessible over the counter and can be assumed by CGM patients without medical supervision, many other chemicals are frequently used to treat critically ill patients. Continuous glucose monitoring reading accuracy may also be compromised in patients characterized by abnormally high concentrations of physiological interferents. In this article, 22 species selected from endogenous and exogenous chemicals were screened as possible interferents of GlucoMen®Day (GMD), the new microdialysis-based CGM system from A. Menarini Diagnostics.

methodInterference testing was performed according to the EP7-A2 guideline (Clinical and Laboratory Standards Institute 2005). Interference was evaluated at two levels of glucose, with each interferent additionally tested at two concentrations. Furthermore, two configurations of the GMD disposable sensor kit--one designed for subcutaneous application, the other for direct intravascular CGM--were challenged with interferent-spiked serum and blood samples, respectively.

resultsWith the exception of dopamine (however, at very high, nonphysiological concentrations), no interference was observed for all the tested substances. Interestingly, none of the common electrochemical interferents (including ascorbic acid, acetaminophen, and salicylic acid, which represent the major specificity issue for the competing CGM systems) significantly affected the system's output.

conclusionsThese results provide clear insights into the advantages offered by the use of a microdialysis-based CGM system that additionally relies on the detection of hydrogen peroxide at low operating potential. GlucoMen Day may become the CGM system of choice for those patients who require either regular administration of drugs or their glycemia to be tightly controlled in the intensive care unit or similar environments.

Indexed as

High-Throughput Screening AssaysBiosensing TechniquesBlood GlucoseBlood Glucose Self-MonitoringCarbohydratesCircadian RhythmCritical IllnessElectrochemical TechniquesEnzyme AssaysEnzymesEquipment Failure AnalysisFalse Positive ReactionsHumansMicrodialysisOrganic ChemicalsBlood GlucoseCarbohydratesEnzymesOrganic Chemicals

Identifiers

PMID23063044
PMCPMC3570852
OpenAlexW2107897242

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.