Evidence map›Paper›PMID 23063041›Full record

Trial reportJournal of diabetes science and technology2012

Inpatient studies of a Kalman-filter-based predictive pump shutoff algorithm.

Fraser Cameron, Darrell M Wilson, Bruce A Buckingham, Hasmik Arzumanyan, Paula Clinton, H Peter Chase, John Lum, David M Maahs, Peter M Calhoun, B Wayne Bequette

Open access · bronzeAbstract readClinical Trial
In one paragraph

Trial report in Journal of diabetes science and technology, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 26 papers.

0numbers the graph read from it
0cells of the map it votes in
26citing papers in PubMed
4.8field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

26 citing papers in PubMed, 57 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Trial
  4. Trial
  5. Trial
  6. Trial
  7. Trial
  8. Trial
  9. Artificial Intelligence in Diabetes Care: Applications, Challenges, and Opportunities Ahead.Endocrine practice : official journal of the American College of Endocrinology and the American Association of Clinical Endocrinologists · 2025
    Review
  10. Article
  11. Feature-Based Machine Learning Model for Real-Time Hypoglycemia Prediction.Journal of diabetes science and technology · 2021
    Article
  12. Article
  13. Article
  14. Review
  15. Review
  16. Review
  17. Review
  18. Hypo- and Hyperglycemic Alarms: Devices and Algorithms.Journal of diabetes science and technology · 2015
    Review
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 4 institutions in 1 country.

Fraser CameronDepartment of Chemical and Biological Engineering, Rensselaer Polytechnic Institute, Troy, New York, USA. fmccamer@gmail.com
Darrell M Wilson
Bruce A Buckingham
Hasmik Arzumanyan
Paula Clinton
H Peter Chase
John Lum
David M Maahs
Peter M Calhoun
B Wayne Bequette
Stanford University · USJaeb Center for Health Research · USRensselaer Polytechnic Institute · USUniversity of Colorado Anschutz Medical Campus · US

Funding

Spectrum Stanford Center for clinical and Translational Research and EducationUL1TR001085 · NCATS · STANFORD UNIVERSITY · PI CULLEN, MARK RICHARD, GREENBERG, HARRY BERNARD · 2013 to 2017
$37.1M
Stanford Center for Clinical and Translational Education and Research (SCCTER)UL1UL1RR025744 · NCRR · STANFORD UNIVERSITY · PI GREENBERG, HARRY BERNARD · 2008 to 2011
$22.4M
In home closed loop reduction of nocturnal hypoglycemia and daytime hyperglycemiaR01DK085591 · NIDDK · JAEB CENTER FOR HEALTH RESEARCH, INC. · PI BECK, ROY W., BUCKINGHAM, BRUCE A · 2009 to 2013
$3.9M
NCATS NIH HHS UL1 TR001085NCRR NIH HHS UL1 RR025744NIDDK NIH HHS 5R01DK085591-03NIDDK NIH HHS R01 DK085591
6 · The paper itself

Abstract

backgroundAn insulin pump shutoff system can prevent nocturnal hypoglycemia and is a first step on the pathway toward a closed-loop artificial pancreas. In previous pump shutoff studies using a voting algorithm and a 1 min continuous glucose monitor (CGM), 80% of induced hypoglycemic events were prevented.

methodsThe pump shutoff algorithm used in previous studies was revised to a single Kalman filter to reduce complexity, incorporate CGMs with different sample times, handle sensor signal dropouts, and enforce safety constraints on the allowable pump shutoff time.

resultsRetrospective testing of the new algorithm on previous clinical data sets indicated that, for the four cases where the previous algorithm failed (minimum reference glucose less than 60 mg/dl), the mean suspension start time was 30 min earlier than the previous algorithm. Inpatient studies of the new algorithm have been conducted on 16 subjects. The algorithm prevented hypoglycemia in 73% of subjects. Suspension-induced hyperglycemia is not assessed, because this study forced excessive basal insulin infusion rates.

conclusionsThe new algorithm functioned well and is flexible enough to handle variable sensor sample times and sensor dropouts. It also provides a framework for handling sensor signal attenuations, which can be challenging, particularly when they occur overnight.

Indexed as

AlgorithmsInpatientsInsulin Infusion SystemsAdultBiosensing TechniquesBlood GlucoseBlood Glucose Self-MonitoringCircadian RhythmDiabetes Mellitus, Type 1Electronic Data ProcessingEquipment DesignEquipment Failure AnalysisHumansHypoglycemic AgentsInsulinRetrospective StudiesBlood GlucoseHypoglycemic AgentsInsulin

Identifiers

PMID23063041
PMCPMC3570849
OpenAlexW2047260582

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.