Evidence map›Paper›PMID 23063040›Full record

Trial reportJournal of diabetes science and technology2012

Robust fault detection system for insulin pump therapy using continuous glucose monitoring.

Pau Herrero, Remei Calm, Josep Vehí, Joaquim Armengol, Pantelis Georgiou, Nick Oliver, Christofer Tomazou

2 registry-linked trialsOpen access · bronzeAbstract readClinical Trial
In one paragraph

Trial report in Journal of diabetes science and technology, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 18 papers.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed
2.7field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT03186300 nacompletednot on this mapstarted 2017, after this paper: background citation

Patient Empowerment Through Predictive Personalised Decision Support (PEPPER)

TypeinterventionalSponsorInstitut d'Investigació Biomèdica de Girona Dr. Josep TruetaRan2017 to 2018Enrolled8ConditionsDiabetes Mellitus, Type 1ArmsPEPPER system
NCT03849755 nacompletednot on this mapstarted 2018, after this paper: background citation

Patient Empowerment Through Predictive Personalised Decision Support(PEPPER)-Validation Study.

TypeinterventionalSponsorInstitut d'Investigació Biomèdica de Girona Dr. Josep TruetaRan2018 to 2019Enrolled58ConditionsDiabetes Mellitus, Type 1ArmsPEPPER system
3 · Its place in the literature

Who cites it

18 citing papers in PubMed, 52 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Review
  15. Fault detection and safety in closed-loop artificial pancreas systems.Journal of diabetes science and technology · 2014
    Review
  16. Article
  17. Article
  18. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 2 countries.

Pau HerreroCenter for Bio-Inspired Technology, Institute of Biomedical Engineering, Imperial College London, South Kensington Campus, London, United Kingdom. pherrero@imperial.ac.uk
Remei Calm
Josep Vehí
Joaquim Armengol
Pantelis Georgiou
Nick Oliver
Christofer Tomazou
Imperial College London · GBUniversity of Girona · ES

Funding

Wellcome Trust
6 · The paper itself

Abstract

backgroundThe popularity of continuous subcutaneous insulin infusion (CSII), or insulin pump therapy, as a way to deliver insulin more physiologically and achieve better glycemic control in diabetes patients has increased. Despite the substantiated therapeutic advantages of using CSII, its use has also been associated with an increased risk of technical malfunctioning of the device, which leads to an increased risk of acute metabolic complications, such as diabetic ketoacidosis. Current insulin pumps already incorporate systems to detect some types of faults, such as obstructions in the infusion set, but are not able to detect other types of fault such as the disconnection or leakage of the infusion set.

methodsIn this article, we propose utilizing a validated robust model-based fault detection technique, based on interval analysis, for detecting disconnections of the insulin infusion set. For this purpose, a previously validated metabolic model of glucose regulation in type 1 diabetes mellitus (T1DM) and a continuous glucose monitoring device were used. As a first step to assess the performance of the presented fault detection system, a Food and Drug Administration-accepted T1DM simulator was employed.

resultsOf the 100 in silico tests (10 scenarios on 10 subjects), only two false negatives and one false positive occurred. All faults were detected before plasma glucose concentration reached 300 mg/dl, with a mean plasma glucose detection value of 163 mg/dl and a mean detection time of 200 min.

conclusionsInterval model-based fault detection has been proven (in silico) to be an effective tool for detecting disconnection faults in sensor-augmented CSII systems. Proper quantification of the uncertainty associated with the employed model has been observed to be crucial for the good performance of the proposed approach.

Indexed as

Insulin Infusion SystemsAdultAlgorithmsBlood Glucose Self-MonitoringComputer SimulationDiabetes Mellitus, Type 1Diagnostic ErrorsEquipment Failure AnalysisHumansHyperglycemiaHypoglycemiaHypoglycemic AgentsInsulinMedication ErrorsModels, BiologicalModels, TheoreticalHypoglycemic AgentsInsulin

Identifiers

PMID23063040
PMCPMC3570848
OpenAlexW1996070385

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.