ArticleJournal of diabetes science and technology2012
System accuracy evaluation of 43 blood glucose monitoring systems for self-monitoring of blood glucose according to DIN EN ISO 15197.
Article in Journal of diabetes science and technology, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 91 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
91 citing papers in PubMed.
- Trial
- Acute Flaxseed Intake Reduces Postprandial Glycemia in Subjects with Type 2 Diabetes: A Randomized Crossover Clinical Trial.Nutrients · 2022Trial
- Trial
- Trial
- A Comprehensive Performance Evaluation of Five Blood Glucose Systems in the Hypo-, Eu-, and Hyperglycemic Range.Journal of diabetes science and technology · 2016Trial
- Clinical accuracy of a continuous glucose monitoring system with an advanced algorithm.Journal of diabetes science and technology · 2015Trial
- Associations Between Carbohydrate Intake Behaviours and Glycaemia in Gestational Diabetes: A Prospective Observational Study.Nutrients · 2025Observational
- Article
- The rising prevalence of type 2 diabetes among the youth in southern India-An ancillary analysis of the Secular TRends in DiabEtes in India (STRiDE-I) study.Journal of diabetes · 2024Observational
- Quality assessment of glucose measurement with regard to epidemiology and clinical management of diabetes mellitus in Germany.Frontiers in molecular biosciences · 2024Article
- Direct Electron Transfer of Glucose Oxidase on Pre-Anodized Paper/Carbon Electrodes Modified through Zero-Length Cross-Linkers for Glucose Biosensors.Biosensors · 2023Article
- Endosperm structure and Glycemic Index of Japonica Italian rice varieties.Frontiers in plant science · 2023Article
- Vulnerability of NCDs and Mediating Effect of Risk Behaviors Among Tuberculosis Patients and Their Household Contacts Compared to the General Population in the Yangon Region, Myanmar.International journal of general medicine · 2023Article
- Current and future therapies to treat impaired awareness of hypoglycemia.Frontiers in pharmacology · 2023Review
- Impact of Two Different Reference Measurement Procedures on Apparent System Accuracy of 18 CE-Marked Current-Generation Blood Glucose Monitoring Systems.Journal of diabetes science and technology · 2022Article
- Clinical Study of a High Accuracy Green Design Blood Glucose Monitor Using an Innovative Optical Transmission Absorbance System.Journal of diabetes science and technology · 2022Article
- Mean Absolute Relative Difference of Blood Glucose Monitoring Systems and Relationship to ISO 15197.Journal of diabetes science and technology · 2022Article
- Do We Need the Replacement of YSI 2300? A View from the Clinical Laboratory.Journal of diabetes science and technology · 2022Article
- Evaluation of Glycemic Index of Six Different Samples of Commercial and Experimental Pasta Differing in Wheat Varieties and Production Processes.Foods (Basel, Switzerland) · 2021Article
- Article
31 more citing papers are in PubMed but not listed here.
Corrections and comments
- Commented on by
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe accuracy of systems for self-monitoring of blood glucose is important, as reliable measurement results are a prerequisite for therapeutic decisions.
methodsThis system accuracy evaluation study was performed according to DIN EN ISO 15197:2003 for 43 Conformité Européenne (CE)-labeled blood glucose (BG) monitoring systems. Measurement results of each system were compared with results of the designated comparison method (manufacturer's measurement procedure): glucose oxidase method (YSI 2300 glucose analyzer) or hexokinase method (Hitachi 917/ cobas 501).
resultsComplete assessment according to the International Organization for Standardization (ISO) standard was performed for 34 out of 43 systems, and 27 (79.4%) meet the requirements of the standard, i.e., ≥95% of their results showed at least the minimum acceptable accuracy. For 9 of the 43 systems, complete accuracy assessment was not performed due to an oxygen sensitivity (manufacturer's labeling). The bias (according to Bland and Altman) of all 43 evaluated systems ranged from -14.1% to +12.4%.
conclusionsFrom the 34 systems completely assessed, 7 systems did not fulfill the minimal accuracy requirements of the ISO standard. The CE mark apparently does not guarantee that all BG systems provide accuracy according to the standard. Because inaccurate systems bear the risk of false therapeutic decisions, regular and standardized evaluation of BG meters and test strips should be requested in order to ensure adherence to quality standards.