Evidence map›Paper›PMID 23052124›Full record

ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2013

Constraints in posterior-stabilised TKA kinematics: a comparison of two generations of an implant.

Hemant Pandit, Bernard Hendrik van Duren, M Price, S Tilley, Harinderjit Singh Gill, Neil P Thomas, David W Murray

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.5field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 12 citations in OpenAlex.

  1. Open medicine (Warsaw, Poland) · 2022
    Article
  2. Varus femoral and tibial coronal alignments result in different kinematics and kinetics after total knee arthroplasty.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2017
    Article
  3. Article
  4. Geometric variable designs of cam/post mechanisms influence the kinematics of knee implants.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2014
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 2 countries.

Hemant PanditNuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences (NDORMS) Nuffield Orthopaedic Centre (NOC), University of Oxford, Headington, Oxford, UK.
Bernard Hendrik van Duren
M Price
S Tilley
Harinderjit Singh Gill
Neil P Thomas
David W Murray
Basingstoke and North Hampshire Hospital · GBNuffield Orthopaedic Centre · GBUniversity of Oxford · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study tests the hypothesis that the design changes incorporated in the newer generation Triathlon posterior-stabilised TKA design result in kinematics that more closely reproduce the kinematics observed in healthy knees than those achieved by the older generation Scorpio posterior-stabilised TKA design.

methodsEleven patients with Triathlon posterior-stabilised TKA, twelve patients with Scorpio posterior-stabilised TKA, and 22 subjects with normal asymptomatic knees underwent fluoroscopic assessment of the knee during a step-up exercise and a weight-bearing deep knee bend. Two-dimensional and three-dimensional knee kinematics were assessed including the maximum flexion, the patella tendon angle (PTA), the patella flexion angle (PFA), the minimum distance between cam and post, and the tibio-femoral contact positions.

resultsThe average maximum flexion achieved was 114° (SD 3°), 91° (SD 10°), and 143° (SD 14°) for the Triathlon, Scorpio, and Normal groups. The average cam/post mechanism engagement was at 63° (SD 24°) and 82° (SD 16°) for the Triathlon and Scorpio groups. The condylar contact points showed a paradoxical anterior slide for the Scorpio group which was not present in the Triathlon group. The PTA and PFA values of both implants showed significant differences from normal.

conclusionOverall, the Triathlon implant design, as compared to Scorpio TKA, produced kinematics closer to that of normal knees as proposed by the hypothesis. However, despite being closer to normal, the kinematics exhibited by the Triathlon group were still different from normal. A comparison of kinematic performance, taking into account altered design parameters, will contribute to improved understanding and future design considerations.

Indexed as

Knee ProsthesisAdultArthroplasty, Replacement, KneeBiomechanical PhenomenaCase-Control StudiesFemaleFemurFluoroscopyHumansMalePatellaPatellar LigamentProsthesis DesignRange of Motion, ArticularRetrospective StudiesTibia

Identifiers

PMID23052124
OpenAlexW2058922519

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.