ReviewAnatomical record (Hoboken, N.J. : 2007)2012
Progress toward development of a multichannel vestibular prosthesis for treatment of bilateral vestibular deficiency.
Review in Anatomical record (Hoboken, N.J. : 2007), 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 5 registered trials, which are not on this map. Cited by 27 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
First-in-Human Early Feasibility Study of Safety, Tolerability and Efficacy for a Multichannel Vestibular Implant in Individuals With Bilateral Severe-to-Profound Loss of Vestibular Sensation
Vestibular Implantation to Treat Adult-Onset Bilateral Vestibular Hypofunction
Vestibular Implantation in Older Adults
Long Term Outcomes After Vestibular Implantation
Vestibular Implant Tested in Patients With Peripheral Vestibular Damage: Effects on Spatial Orientation, Navigation, and Neuropsychologic Function
Who cites it
27 citing papers in PubMed, 61 citations in OpenAlex.
- An adaptive vestibular rehabilitation technique.The Laryngoscope · 2018Trial
- Perceptual response characterization in acute vestibular implant stimulation.Journal of neurology · 2025Article
- How a Subclinical Unilateral Vestibular Signal Improves Binocular Vision.Journal of clinical medicine · 2023Article
- Vestibular prosthesis: from basic research to clinics.Frontiers in integrative neuroscience · 2023Review
- Computer Simulation of the Electrical Stimulation of the Human Vestibular System: Effects of the Reactive Component of Impedance on Voltage Waveform and Nerve Selectivity.Journal of the Association for Research in Otolaryngology : JARO · 2022Article
- A Hydrogel-Based Microfluidic Nerve Cuff for Neuromodulation of Peripheral Nerves.Micromachines · 2021Article
- Influence of systematic variations of the stimulation profile on responses evoked with a vestibular implant prototype in humans.Journal of neural engineering · 2020Article
- Finding a Balance: A Systematic Review of the Biomechanical Effects of Vestibular Prostheses on Stability in Humans.Journal of functional morphology and kinesiology · 2020Review
- [Current status and new progress of vestibular assistant systems].Lin chuang er bi yan hou tou jing wai ke za zhi = Journal of clinical otorhinolaryngology head and neck surgery · 2020Review
- Binocular 3D otolith-ocular reflexes: responses of chinchillas to prosthetic electrical stimulation targeting the utricle and saccule.Journal of neurophysiology · 2020Article
- The vestibular implant: Opinion statement on implantation criteria for research.Journal of vestibular research : equilibrium & orientation · 2020Review
- Nonhuman primate vestibuloocular reflex responses to prosthetic vestibular stimulation are robust to pulse timing errors caused by temporal discretization.Journal of neurophysiology · 2019Article
- Cochlear Implants and Children with Vestibular Impairments.Seminars in hearing · 2018Review
- The Dynamics of Prosthetically Elicited Vestibulo-Ocular Reflex Function Across Frequency and Context in the Rhesus Monkey.Frontiers in neuroscience · 2018Article
- Analysis of Vestibular Labyrinthine Geometry and Variation in the Human Temporal Bone.Frontiers in neuroscience · 2018Article
- Model-Based Vestibular Afferent Stimulation: Evaluating Selective Electrode Locations and Stimulation Waveform Shapes.Frontiers in neuroscience · 2018Article
- The Vestibular Implant Input Interacts with Residual Natural Function.Frontiers in neurology · 2017Article
- Model-based Vestibular Afferent Stimulation: Modular Workflow for Analyzing Stimulation Scenarios in Patient Specific and Statistical Vestibular Anatomy.Frontiers in neuroscience · 2017Article
- Characterization of Cochlear, Vestibular and Cochlear-Vestibular Electrically Evoked Compound Action Potentials in Patients with a Vestibulo-Cochlear Implant.Frontiers in neuroscience · 2017Article
- A CMOS Neural Interface for a Multichannel Vestibular Prosthesis.IEEE transactions on biomedical circuits and systems · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 2 institutions in 1 country.
Funding
Abstract
This article reviews vestibular pathology and the requirements and progress made in the design and construction of a vestibular prosthesis. Bilateral loss of vestibular sensation is disabling. When vestibular hair cells are injured by ototoxic medications or other insults to the labyrinth, the resulting loss of sensory input disrupts vestibulo-ocular reflexes (VORs) and vestibulo-spinal reflexes that normally stabilize the eyes and body. Affected individuals suffer poor vision during head movement, postural instability, chronic disequilibrium, and cognitive distraction. Although most individuals with residual sensation compensate for their loss over time, others fail to do so and have no adequate treatment options. A vestibular prosthesis analogous to cochlear implants but designed to modulate vestibular nerve activity during head movement should improve quality of life for these chronically dizzy individuals. We describe the impact of bilateral loss of vestibular sensation, animal studies supporting feasibility of prosthetic vestibular stimulation, the current status of multichannel vestibular sensory replacement prosthesis development, and challenges to successfully realizing this approach in clinical practice. In bilaterally vestibular-deficient rodents and rhesus monkeys, the Johns Hopkins multichannel vestibular prosthesis (MVP) partially restores the three-dimensional (3D) VOR for head rotations about any axis. Attempts at prosthetic vestibular stimulation of humans have not yet included the 3D eye movement assays necessary to accurately evaluate VOR alignment, but these initial forays have revealed responses that are otherwise comparable to observations in animals. Current efforts now focus on refining electrode design and surgical technique to enhance stimulus selectivity and preserve cochlear function, optimizing stimulus protocols to improve dynamic range and reduce excitation-inhibition asymmetry, and adapting laboratory MVP prototypes into devices appropriate for use in clinical trials.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.