ArticleCritical care (London, England)2012
Effects of respiratory mechanics on the capnogram phases: importance of dynamic compliance of the respiratory system.
Article in Critical care (London, England), 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 30 citations in OpenAlex.
- Trial
- Activation of Automatic Tube Compensation Mode Attenuates Auto-PEEP in Chronic Obstructive Pulmonary Disease Patients.The clinical respiratory journal · 2024Article
- Volumetric but Not Time Capnography Detects Ventilation/Perfusion Mismatch in Injured Rabbit Lung.Frontiers in physiology · 2018Article
- Capnogram slope and ventilation dead space parameters: comparison of mainstream and sidestream techniques.British journal of anaesthesia · 2016Article
- Year in review 2012: Critical Care--Respirology.Critical care (London, England) · 2013Review
- Effects of thoracic squeezing on airway secretion removal in mechanically ventilated patients.Iranian journal of nursing and midwifery researchArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionThe slope of phase III of the capnogram (SIII) relates to progressive emptying of the alveoli, a ventilation/perfusion mismatch, and ventilation inhomogeneity. S(III) depends not only on the airway geometry, but also on the dynamic respiratory compliance (Crs); this latter effect has not been evaluated. Accordingly, we established the value of SIII for monitoring airway resistance during mechanical ventilation.
methodsSidestream capnography was performed during mechanical ventilation in patients undergoing elective cardiac surgery (n = 144). The airway resistance (Raw), total respiratory resistance and Crs displayed by the ventilator, the partial pressure of arterial oxygen (PaO2) and S(III) were measured in time domain (S(T-III)) and in a smaller cohort (n = 68) by volumetry (S(V-III)) with and without normalization to the average CO2 phase III concentration. Measurements were performed at positive end-expiratory pressure (PEEP) levels of 3, 6 and 9 cmH2O in patients with healthy lungs (Group HL), and in patients with respiratory symptoms involving low (Group LC), medium (Group MC) or high Crs (Group HC).
resultsS(T-III) and S(V-III) exhibited similar PEEP dependencies and distribution between the protocol groups formed on the basis of Crs. A wide interindividual scatter was observed in the overall Raw-S(T-III) relationship, which was primarily affected by Crs. Decreases in Raw with increasing PEEP were reflected in sharp falls in S(III) in Group HC, and in moderate decreases in S(III) in Group MC, whereas S(T-III) was insensitive to changes in airway caliber in Groups LC and HL.
conclusionsSIII assessed in the time domain and by volumetry provide meaningful information about alterations in airway caliber, but only within an individual patient. Although S(T-III) may be of value for bedside monitoring of the airway properties, its sensitivity depends on Crs. Thus, assessment of the capnogram shape should always be coupled with Crs when the airway resistance or oxygenation are evaluated.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.