Evidence map›Paper›PMID 23016927›Full record

ArticleBMC medical imaging2012

Dynamic ultrasound imaging--a multivariate approach for the analysis and comparison of time-dependent musculoskeletal movements.

Tommy Löfstedt, Olof Ahnlund, Michael Peolsson, Johan Trygg

Abstract readComparative Study
In one paragraph

Article in BMC medical imaging, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
  4. Review
  5. Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Tommy LöfstedtComputational Life Science Cluster (CLiC), Department of Chemistry, Umeå University, Umeå, Sweden.
Olof Ahnlund
Michael Peolsson
Johan Trygg

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMuscle functions are generally assumed to affect a wide variety of conditions and activities, including pain, ischemic and neurological disorders, exercise and injury. It is therefore very desirable to obtain more information on musculoskeletal contributions to and activity during clinical processes such as the treatment of muscle injuries, post-surgery evaluations, and the monitoring of progressive degeneration in neuromuscular disorders.The spatial image resolution achievable with ultrasound systems has improved tremendously in the last few years and it is nowadays possible to study skeletal muscles in real-time during activity. However, ultrasound imaging has an inherent problem that makes it difficult to compare different measurement series or image sequences from two or more subjects. Due to physiological differences between different subjects, the ultrasound sequences will be visually different - partly because of variation in probe placement and partly because of the difficulty of perfectly reproducing any given movement.

methodsUltrasound images of the biceps and calf of a single subject were transformed to achieve congruence and then efficiently compressed and stacked to facilitate analysis using a multivariate method known as O2PLS. O2PLS identifies related and unrelated variation in and between two sets of data such that different phases of the studied movements can be analysed. The methodology was used to study the dynamics of the Achilles tendon and the calf and also the Biceps brachii and upper arm. The movements of these parts of the body are both of interest in clinical orthopaedic research.

resultsThis study extends the novel method of multivariate analysis of congruent images (MACI) to facilitate comparisons between two series of ultrasound images. This increases its potential range of medical applications and its utility for detecting, visualising and quantifying the dynamics and functions of skeletal muscle.

conclusionsThe most important results of this study are that MACI with O2PLS is able to consistently extract meaningful variability from pairs of ultrasound sequences. The MACI method with O2PLS is a powerful tool with great potential for visualising and comparing dynamics between movements. It has many potential clinical applications in the study of muscle injuries, post-surgery evaluations and evaluations of rehabilitation, and the assessment of athletic training interventions.

Indexed as

Subtraction TechniqueAlgorithmsAnkle JointData Interpretation, StatisticalHumansImage EnhancementImage Interpretation, Computer-AssistedLeast-Squares AnalysisMovementMultivariate AnalysisMuscle, SkeletalPattern Recognition, AutomatedReproducibility of ResultsSensitivity and SpecificityUltrasonography

Identifiers

PMID23016927
PMCPMC3570433

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.