ArticleDer Anaesthesist2012
[EzPAP® therapy of postoperative hypoxemia in the recovery room : experiences with the new compact system of end-expiratory positive airway pressure].
Article in Der Anaesthesist, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 6 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
The Effect of Timing of Intravenous Paracetamol Administration on Post-surgical Pain and Cytokines Levels Following Laparoscopic Sleeve Gastrectomy
Reflections of Oxygen Delivery Methods Applied in Acute Exacerbations of Chronic Obstructive Pulmonary Disease (COPD) on Blood Gas and Spirometer Measurements
Who cites it
6 citing papers in PubMed, 1 synthesis or guideline pooled it, 15 citations in OpenAlex.
- Continuous positive airway pressure (CPAP) during the postoperative period for prevention of postoperative morbidity and mortality following major abdominal surgery.The Cochrane database of systematic reviews · 2014Pooled it
- Comparison of positive expiratory pressure device versus non-invasive ventilation on outcomes in acute exacerbation of chronic obstructive pulmonary disease in the emergency department.BMC emergency medicine · 2025Trial
- Effect of the EzPAP system on tidal volume and airway pressures in healthy adults.Canadian journal of respiratory therapy : CJRT = Revue canadienne de la therapie respiratoire : RCTR · 2026Article
- Barriers to and Facilitators for Acceptance of Comprehensive Clinical Decision Support System-Driven Care Maps for Patients With Thoracic Trauma: Interview Study Among Health Care Providers and Nurses.JMIR human factors · 2022Article
- Chest physiotherapy: An important adjuvant in critically ill mechanically ventilated patients with COVID-19.Respiratory physiology & neurobiology · 2020Review
- The effects of repeated propofol anesthesia on spatial memory and long-term potentiation in infant rats under hypoxic conditions.Genes & diseases · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundPostoperative hypoxemia is a common complication in the anesthesia recovery room (ARR), which is predominantly based on the development of atelectasis, excessive intraoperative fluid shift and insufficient ventilation. The goal of this prospective observational study was to compare the effect of standard oxygen administration via a face mask with oxygen administration using the EzPAP® system, a device which additionally provides a positive end-expiratory pressure (PEEP).
methodsThis study included 210 patients with postoperative hypoxemia (S(p)O(2) < 93%) subdivided into the control group (105 patients) and the EzPAP group (105 patients). Postoperative residual paralysis was excluded using relaxometry and a train of four (TOF) ratio of 0.9 was assumed to ensure sufficient recovery of respiratory function from neuromuscular blockade. Patients who received a reversal of neuromuscular blockade were excluded. In cases of hypoxemia (S(p)O(2) < 93%) control patients were treated with oxygen (6 l/min) using a face mask, whereas the EzPAP group received oxygen using the EzPAP® system. In order to adjust the PEEP in the EzPAP group, the O(2) flow was verified and measured by a manometer. After 1 h of oxygen therapy, the oxygen supply was stopped. In cases of reoccurring hypoxemia (S(p)O(2) < 93%, persistence > 5 min), the oxygen therapy was restarted in both groups via a facemask. Both groups were compared using repeat measurement analysis of variance (ANOVA), the unpaired t-test, the Mann-Whitney U-test, Fisher's exact test and the χ(2)-test. The correlation of O(2) flow and PEEP was evaluated by regression analysis and p < 0.05 was considered to be statistically significant. Apart from this a subgroup analysis was performed depending on body-mass index (BMI), American Society of Anesthesiologists (ASA) classification, intraoperative airway management, the use of neuromuscular blocking agents and co-existing disorders, e.g. chronic obstructive lung disease (COLD), obesity and chronic heart failure.
resultsAll patients were equally distributed between both groups with respect to demographic data, ASA classification, BMI, co-existing disorders and surgical procedures. The S(p)O(2) values did not differ between the EzPAP patients and the control group, except for 0.5 min after initiation of oxygen therapy: EzPAP group 96 ± 3.7% (mean ± standard deviation) versus the control group 93.8 ± 4.4% (p < 0.001). However, restarting oxygen therapy was less common in the EzPAP group (EzPAP group 25 versus control group 41, p = 0.03), as well as the occurrence of postoperative complications (EzPAP group 13 versus control group 25, p = 0.02), e.g. nosocomial pneumonia (0 versus 4) and wound infections (2 versus 3). Furthermore, patients with obesity and pulmonary disorders, such as COLD had a benefit from oxygen administration using the EzPAP device and showed higher postoperative than preoperative S(p)O(2) values. In contrast, the subgroup analysis of patients with heart failure did not reveal any differences between both groups and both groups did not differ in terms of time spent in the recovery room (EzPAP group 113 min versus control group 174.8 min, p = 0.2).
conclusionsIn this observational study oxygen supply using the EzPAP® system appeared to be at least equally as effective in the therapy of postoperative hypoxemia compared to standard oxygen supply using a face mask. In patients with a high risk of postoperative hypoxemia, such as patients with obesity and/or pulmonary disorders, oxygen administration using the EzPAP® system possibly improves pulmonary oxygenation more effectively and is longer lasting compared to standard oxygen supply via a face mask. Hence, the EzPAP® system represents a well-tolerated, effective, cost-effective and easily operated tool to improve postoperative oxygenation. In order to investigate the possibilities of this promising tool more intensively, randomized clinical trials are warranted.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.