Evidence map›Paper›PMID 23010690›Full record

ArticlePhysics in medicine and biology2012

Pulse shape discrimination and classification methods for continuous depth of interaction encoding PET detectors.

Emilie Roncali, Jennifer E Phipps, Laura Marcu, Simon R Cherry

Abstract read
In one paragraph

Article in Physics in medicine and biology, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Review
  2. Investigation of a Model-based Time-over-threshold Technique for Phoswich Crystal Discrimination.IEEE transactions on radiation and plasma medical sciences · 2022
    Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Emilie RoncaliDepartment of Biomedical Engineering, University of California Davis, One Shields Avenue, Davis, CA 95616, USA. eroncali@ucdavis.edu
Jennifer E Phipps
Laura Marcu
Simon R Cherry

Funding

Time-Resolved Spectroscopy of Unstable Arterial PlaquesR01HL067377 · NHLBI · UNIVERSITY OF CALIFORNIA AT DAVIS · PI MARCU, LAURA · 2001 to 2015
$5.2M
Development of a Small Animal PET Scanner Using Solid State PhotomultipliersR01CA134632 · NCI · UNIVERSITY OF CALIFORNIA AT DAVIS · PI CHERRY, SIMON R, SHAH, KANAI · 2008 to 2012
$2.1M
NCI NIH HHS CA134632NCI NIH HHS R01 CA134632NHLBI NIH HHS R01 HL067377
6 · The paper itself

Abstract

In previous work we demonstrated the potential of positron emission tomography (PET) detectors with depth-of-interaction (DOI) encoding capability based on phosphor-coated crystals. A DOI resolution of 8 mm full-width at half-maximum was obtained for 20 mm long scintillator crystals using a delayed charge integration linear regression method (DCI-LR). Phosphor-coated crystals modify the pulse shape to allow continuous DOI information determination, but the relationship between pulse shape and DOI is complex. We are therefore interested in developing a sensitive and robust method to estimate the DOI. Here, linear discriminant analysis (LDA) was implemented to classify the events based on information extracted from the pulse shape. Pulses were acquired with 2×2×20 mm(3) phosphor-coated crystals at five irradiation depths and characterized by their DCI values or Laguerre coefficients. These coefficients were obtained by expanding the pulses on a Laguerre basis set and constituted a unique signature for each pulse. The DOI of individual events was predicted using LDA based on Laguerre coefficients (Laguerre-LDA) or DCI values (DCI-LDA) as discriminant features. Predicted DOIs were compared to true irradiation depths. Laguerre-LDA showed higher sensitivity and accuracy than DCI-LDA and DCI-LR and was also more robust to predict the DOI of pulses with higher statistical noise due to low light levels (interaction depths further from the photodetector face). This indicates that Laguerre-LDA may be more suitable to DOI estimation in smaller crystals where lower collected light levels are expected. This novel approach is promising for calculating DOI using pulse shape discrimination in single-ended readout depth-encoding PET detectors.

Indexed as

AlgorithmsDiscriminant AnalysisImage Processing, Computer-AssistedLinear ModelsPositron-Emission TomographyTime Factors

Identifiers

PMID23010690
PMCPMC3482627

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.