Trial reportDiabetes technology & therapeutics2012
Evaluation of a novel continuous glucose monitoring-based method for mealtime insulin dosing--the iBolus--in subjects with type 1 diabetes using continuous subcutaneous insulin infusion therapy: a randomized controlled trial.
Trial report in Diabetes technology & therapeutics, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 1 synthesis or guideline pooled it, 21 citations in OpenAlex.
- Effectiveness and safety of carbohydrate counting in the management of adult patients with type 1 diabetes mellitus: a systematic review and meta-analysis.Archives of endocrinology and metabolism · 2018Pooled it
- Trial
- Preliminary evaluation of a new semi-closed-loop insulin therapy system over the prandial period in adult patients with type 1 diabetes: the WP6.0 Diabeloop study.Journal of diabetes science and technology · 2014Trial
- Continuous glucose monitoring for automatic real-time assessment of eating events and nutrition: a scoping review.Frontiers in nutrition · 2023Article
- Artificial Intelligence in Decision Support Systems for Type 1 Diabetes.Sensors (Basel, Switzerland) · 2020Review
- Dynamic Rule-Based Algorithm to Tune Insulin-on-Board Constraints for a Hybrid Artificial Pancreas System.Journal of healthcare engineering · 2020Article
- Suspension of basal insulin to avoid hypoglycemia in type 1 diabetes treated with insulin pump.Endocrinology, diabetes & metabolism case reports · 2015Article
- Novel insulin delivery profiles for mixed meals for sensor-augmented pump and closed-loop artificial pancreas therapy for type 1 diabetes mellitus.Journal of diabetes science and technology · 2014Article
- Use of Automated Bolus Calculators for Diabetes Management.European endocrinology · 2013Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivePrandial insulin dosing is an empirical practice associated frequently with poor reproducibility in postprandial glucose response. Based on continuous glucose monitoring (CGM), a method for prandial insulin administration (iBolus) is presented and evaluated for people with type 1 diabetes using CSII therapy. SUBJECTS AND
methodsAn individual patient's model for a 5-h postprandial period was obtained from 6-day ambulatory CGM and used for iBolus calculation in 12 patients with type 1 diabetes. In a double-blind, crossover study each patient underwent four meal tests with 40 g or 100 g of carbohydrates (CHOs), both on two occasions. For each meal, the iBolus or the traditional bolus (tBolus) was given before mealtime (t(0)) in a randomized order. We measured the postprandial glycemic response as the area under the curve of plasma glucose (AUC-PG(0-5h)) and variability as the individual coefficient of variation (CV) of AUC-PG(0-5h). The contribution of the insulin-to-CHO ratio, CHO, plasma glucose at t(0) (PG(t0)), and insulin dose to AUC-PG(0-5h) and its CV was also investigated.
resultsAUC-PG(0-5h) was similar with either bolus for 40-g (iBolus vs. tBolus, 585.5±127.5 vs. 689.2±180.7 mg/dL·h) or 100-g (752.1±237.7 vs. 760.0±263.2 mg/dL·h) CHO meals. A multiple regression analysis revealed a significant model only for the tBolus, with PG(t0) being the best predictor of AUC-PG(0-5h) explaining approximately 50% of the glycemic response. Observed variability was greater with the iBolus (CV, 16.7±15.3% vs. 10.1±12.5%) but independent of the factors studied.
conclusionsA CGM-based algorithm for calculation of prandial insulin is feasible, although it does not reduce unpredictability of individual glycemic responses. Causes of variability need to be identified and analyzed for further optimization of postprandial glycemic control.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials