Evidence map›Paper›PMID 22996746›Full record

ArticleRadiology2012

Hyperpolarized water as an MR imaging contrast agent: feasibility of in vivo imaging in a rat model.

Mark D Lingwood, Ting Ann Siaw, Napapon Sailasuta, Osama A Abulseoud, Henry R Chan, Brian D Ross, Pratip Bhattacharya, Songi Han

Abstract read
In one paragraph

Article in Radiology, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers.

0numbers the graph read from it
0cells of the map it votes in
19citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

19 citing papers in PubMed.

  1. Article
  2. Review
  3. Multidimensional pH-Temperature Mapping of SABRE-SHEATHThe journal of physical chemistry. B · 2025
    Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
  12. Article
  13. A New Ir-NHC Catalyst for Signal Amplification by Reversible Exchange in D2 O.Chemistry (Weinheim an der Bergstrasse, Germany) · 2016
    Article
  14. Article
  15. Nanoscale Catalysts for NMR Signal Enhancement by Reversible Exchange.The journal of physical chemistry. C, Nanomaterials and interfaces · 2015
    Article
  16. NMR hyperpolarization techniques for biomedicine.Chemistry (Weinheim an der Bergstrasse, Germany) · 2015
    Article
  17. Heterogeneous solution NMR signal amplification by reversible exchange.Angewandte Chemie (International ed. in English) · 2014
    Article
  18. Review
  19. Overhauser Dynamic Nuclear Polarization-Enhanced NMR Relaxometry.Microporous and mesoporous materials : the official journal of the International Zeolite Association · 2013
    Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

8 authors.

Mark D LingwoodDepartment of Chemistry, University of California, Santa Barbara, Mesa Road, Santa Barbara, CA 93106, USA.
Ting Ann Siaw
Napapon Sailasuta
Osama A Abulseoud
Henry R Chan
Brian D Ross
Pratip Bhattacharya
Songi Han

Funding

13C and 15N MRS Study of glutamate control in epilepsyR01NS048589 · NINDS · HUNTINGTON MEDICAL RESEARCH INSTITUTES · PI ROSS, BRIAN DAVID · 2006 to 2009
$1.4M
Ultra-fast 15N Imaging in Choline in CancerR01CA122513 · NCI · HUNTINGTON MEDICAL RESEARCH INSTITUTES · PI ROSS, BRIAN DAVID · 2007 to 2011
$1.0M
PASADENA: Ultra-fast Carbon 13 Imaging for Early Diagnosis of CancerR21CA118509 · NCI · HUNTINGTON MEDICAL RESEARCH INSTITUTES · PI BHATTACHARYA, PRATIP K · 2006 to 2007
$298k
NCI NIH HHS R01 CA122513NCI NIH HHS R21 CA118509NINDS NIH HHS R01 NS048589
6 · The paper itself

Abstract

purposeTo assess the feasibility of a perfusion magnetic resonance (MR) imaging technique that uses Overhauser dynamic nuclear polarization (DNP) to provide contrast during the continuous delivery of hyperpolarized water in rats. MATERIALS AND

methodsProtocols approved by the local institutional animal care and use committees were followed. Twelve male Wistar rats were anesthetized and prepared by placing injection tubing in the subcutaneous layer (n=3), peritoneum (n=3), aorta (n=3), or carotid artery (n=3). Water was hyperpolarized by means of Overhauser DNP in the 0.35-T fringe field of a 1.5-T MR imaging magnet by using a custom-built system to continuously deliver radical-free hyperpolarized water to the subject. Fast gradient-echo and spoiled gradient-recalled-echo MR imaging sequences were used. The signal-to-noise ratio (SNR) of the images was calculated and compared.

resultsImages showed greatly altered SNR and enhanced flow contrast at all injection locations. For subcutaneous and intraperitoneal injections, the water perfusion trajectory was observed for approximately 5 seconds after injection. Flow through a 4.2-cm length of artery was seen during intra-aortic injection. The right hemisphere of the brain was seen during injection into the right carotid artery. Images with hyperpolarized water had greatly altered SNR compared with images without injection or with the injection of nonhyperpolarized water, with a range of 13%-27% for the carotid and 444%-2900% for the other regions.

conclusionPerfusion contrast for MR imaging can be obtained by continuously infusing hyperpolarized water, providing localized angiography or brain perfusion information in vivo for rat models.

Indexed as

AnimalsArteriesBlood Flow VelocityContrast MediaFeasibility StudiesImage EnhancementMagnetic Resonance AngiographyMaleRatsRats, WistarReproducibility of ResultsSensitivity and SpecificityStatic ElectricityWaterContrast MediaWater

Identifiers

PMID22996746
PMCPMC3480810

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked