ArticleISRN cardiology2012
Radiation Dose Reduction during Radial Cardiac Catheterization: Evaluation of a Dedicated Radial Angiography Absorption Shielding Drape.
Article in ISRN cardiology, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed.
- Efficacy of RADPAD protection drape in reducing radiation exposure in the catheterization laboratory-First Indian study.Indian heart journal · 2018Trial
- Advancements in Cardiac Catheterization Safety: Novel Radiation Protection Approaches Redefining Occupational Health.Current cardiology reviews · 2025Review
- Review
- Reduction in Primary Operator Radiation Dose Exposure During Coronary Angioplasty Using Radiation Absorbing Drape.Cureus · 2023Article
- New Radioprotective Device that can be Used for Fluoroscopic Exam: Possibility to Contribute to Staff Exposure Protection During VFSS.Dysphagia · 2022Article
- Radiation protection for the interventional cardiologist: Practical approach and innovations.World journal of cardiology · 2022Review
- Radiation protection in the cardiac catheterization laboratory.Journal of thoracic disease · 2020Review
- Cardiac catheterization real-time dynamic radiation dose measurement to estimate lifetime attributable risk of cancer.PloS one · 2020Article
- The effectiveness of additional lead-shielding drape and low pulse rate fluoroscopy in protecting staff from scatter radiation during cardiac resynchronization therapy (CRT).Japanese journal of radiology · 2019Article
- Article
- Impact of the Ceiling-Mounted Radiation Shielding Position on the Physician's Dose from Scatter Radiation during Interventional Procedures.Radiology research and practice · 2018Article
- A novel radiation protection device based on tungsten functional paper for application in interventional radiology.Journal of applied clinical medical physics · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Objectives. Radiation scatter protection shield drapes have been designed with the goal of decreasing radiation dose to the operators during transfemoral catheterization. We sought to investigate the impact on operator radiation exposure of various shielding drapes specifically designed for the radial approach. Background. Radial access for cardiac catheterization has increased due to improved patient comfort and decreased bleeding complications. There are concerns for increased radiation exposure to patients and operators. Methods. Radiation doses to a simulated operator were measured with a RadCal Dosimeter in the cardiac catheterization laboratory. The mock patient was a 97.5 kg fission product phantom. Three lead-free drape designs were studied. The drapes were placed just proximal to the right wrist and extended medially to phantom's trunk. Simulated diagnostic coronary angiography included 6 minutes of fluoroscopy time and 32 seconds of cineangiography time at 4 standard angulated views (8 s each), both 15 frames/s. ANOVA with Bonferroni correction was used for statistical analysis. Results. All drape designs led to substantial reductions in operator radiation exposure compared to control (P < 0.0001). The greatest decrease in radiation exposure (72%) was with the L-shaped design. Conclusions. Dedicated radial shielding drapes decrease radiation exposure to the operator by up to 72% during simulated cardiac catheterization.
Identifiers
What OpenQuestion holds
Registered trials