ArticleBiomechanics and modeling in mechanobiology2013
Atrial fibrillation pacing decreases intravascular shear stress in a New Zealand white rabbit model: implications in endothelial function.
Article in Biomechanics and modeling in mechanobiology, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 18 citations in OpenAlex.
- Exercise mitigates flow recirculation and activates metabolic transducer SCD1 to catalyze vascular protective metabolites.Science advances · 2024Article
- Association between aortic thrombi detected using non-obstructive general angioscopy and atrial fibrillation.Journal of thrombosis and thrombolysis · 2024Article
- The role of the blood-brain barrier during neurological disease and infection.Biochemical Society transactions · 2023Review
- microRNAs as Biomarkers of Endothelial Dysfunction and Therapeutic Target in the Pathogenesis of Atrial Fibrillation.International journal of molecular sciences · 2023Review
- Construction of a potentially functional lncRNA-miRNA-mRNA network in sepsis by bioinformatics analysis.Frontiers in genetics · 2022Article
- Coronary Endothelial Dysfunction Is Associated With Increased Risk of Incident Atrial Fibrillation.Journal of the American Heart Association · 2020Article
- Flow-Responsive Vascular Endothelial Growth Factor Receptor-Protein Kinase C Isoform Epsilon Signaling Mediates Glycolytic Metabolites for Vascular Repair.Antioxidants & redox signaling · 2018Article
- 4-Dimensional light-sheet microscopy to elucidate shear stress modulation of cardiac trabeculation.The Journal of clinical investigation · 2016Article
- Disturbed Flow Induces Autophagy, but Impairs Autophagic Flux to Perturb Mitochondrial Homeostasis.Antioxidants & redox signaling · 2015Article
- Blood flow modulation of vascular dynamics.Current opinion in lipidology · 2015Review
- Shear stress-activated Wnt-angiopoietin-2 signaling recapitulates vascular repair in zebrafish embryos.Arteriosclerosis, thrombosis, and vascular biology · 2014Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors at 3 institutions in 1 country.
Funding
Abstract
Atrial fibrillation (AF) is characterized by multiple rapid and irregular atrial depolarization, leading to rapid ventricular responses exceeding 100 beats per minute (bpm). We hypothesized that rapid and irregular pacing reduced intravascular shear stress (ISS) with implication to modulating endothelial responses. To simulate AF, we paced the left atrial appendage of New Zealand White rabbits (n = 4) at rapid and irregular intervals. Surface electrical cardiograms were recorded for atrial and ventricular rhythm, and intravascular convective heat transfer was measured by microthermal sensors, from which ISS was inferred. Rapid and irregular pacing decreased arterial systolic and diastolic pressures (baseline, 99/75 mmHg; rapid regular pacing, 92/73; rapid irregular pacing, 90/68; p < 0.001, n = 4), temporal gradients ([Formula: see text] from 1,275 ± 80 to 1,056 ± 180 dyne/cm(2) s), and reduced ISS (from baseline at 32.0 ± 2.4 to 22.7 ± 3.5 dyne/cm(2)). Computational fluid dynamics code demonstrated that experimentally inferred ISS provided a close approximation to the computed wall shear stress at a given catheter to vessel diameter ratio, shear stress range, and catheter position. In an in vitro flow system in which time-averaged shear stress was maintained at [Formula: see text] , we further demonstrated that rapid pulse rates at 150 bpm down-regulated endothelial nitric oxide, promoted superoxide (O 2 (.-) ) production, and increased monocyte binding to endothelial cells. These findings suggest that rapid pacing reduces ISS and [Formula: see text] , and rapid pulse rates modulate endothelial responses.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.