ArticleJournal of magnetic resonance (San Diego, Calif. : 1997)2012
Corrections for sinusoidal background and non-orthogonality of signal channels in sinusoidal rapid magnetic field scans.
Article in Journal of magnetic resonance (San Diego, Calif. : 1997), 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 28 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
28 citing papers in PubMed.
- Compact 1 GHz electron paramagnetic resonance spectrometer and imager.The Review of scientific instruments · 2025Article
- Rapid scan EPR: Automated digital resonator control for low-latency data acquisition.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2022Article
- Advances in rapid scan EPR spectroscopy.Methods in enzymology · 2022Article
- Rapid Scan EPR Oxygen Imaging in Photoactivated Resin Used for Stereolithographic 3D Printing.3D printing and additive manufacturing · 2021Article
- General solution for rapid scan EPR deconvolution problem.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2020Article
- Rapid-scan EPR imaging of a phantom comprised of species with different linewidths and relaxation times.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2019Article
- Modular imaging system: Rapid scan EPR at 800 MHz.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2019Article
- Development of an L-band rapid scan EPR digital console.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2019Article
- Background correction in rapid scan EPR spectroscopy.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2018Article
- Resonators for In Vivo Imaging: Practical Experience.Applied magnetic resonance · 2017Article
- Using rapid-scan EPR to improve the detection limit of quantitative EPR by more than one order of magnitude.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2017Article
- Full cycle rapid scan EPR deconvolution algorithm.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2017Article
- Rapid-scan EPR imaging.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2017Review
- Exchange Phenomena in the Electron Paramagnetic Resonance Spectra of the Nitroxyl and Trityl Radicals: Multifunctional Spectroscopy and Imaging of Local Chemical Microenvironment.Analytical chemistry · 2017Review
- Imaging thiol redox status in murine tumors in vivo with rapid-scan electron paramagnetic resonance.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2017Article
- Rapid scan electron paramagnetic resonance at 1.0 GHz of defect centers in γ-irradiated organic solids.Radiation measurements · 2016Article
- Imaging disulfide dinitroxides at 250 MHz to monitor thiol redox status.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2015Article
- Field-stepped direct detection electron paramagnetic resonance.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2015Article
- X-Band Rapid-Scan Electron Paramagnetic Resonance of Radiation-Induced Defects in Tooth Enamel.Radiation research · 2015Article
- Electron spin relaxation times and rapid scan EPR imaging of pH-sensitive amino-substituted trityl radicals.Magnetic resonance in chemistry : MRC · 2015Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
The rapidly-changing magnetic field of sinusoidal rapid scans creates background signals that are dominated by oscillations at the scan frequency. The background oscillations can be removed without acquiring off-resonance data. For data acquired in quadrature, up-field and down-field scan signals can be separated in the frequency domain. For each scan direction, the background oscillation can be calculated by fitting to the half cycle that does not contain the EPR signal. The extrapolated fit function is then subtracted from the half cycle that contains the EPR signal. By zeroing the array for the half cycles that do not contain the EPR signal, the signal-to-noise is improved and the data are corrected for non-orthogonality of the quadrature channels.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.