Evidence map›Paper›PMID 22959566›Full record

ArticleThe Annals of thoracic surgery2012

In-parallel attachment of a low-resistance compliant thoracic artificial lung under rest and simulated exercise.

Rebecca E Schewe, Christopher N Scipione, Kelly L Koch, Keith E Cook

Abstract read
In one paragraph

Article in The Annals of thoracic surgery, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. A Model of Pediatric End-Stage Lung Failure in Small Lambs <20 kg.ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2020
    Article
  3. Fourteen Day In Vivo Testing of a Compliant Thoracic Artificial Lung.ASAIO journal (American Society for Artificial Internal Organs : 1992)
    Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

4 authors.

Rebecca E ScheweDepartment of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109, USA.
Christopher N Scipione
Kelly L Koch
Keith E Cook

Funding

Compliant Thoracic Artificial LungsR01HL089043 · NHLBI · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI COOK, KEITH E · 2009 to 2017
$4.2M
NHLBI NIH HHS R01 HL089043NHLBI NIH HHS R01HL089043
6 · The paper itself

Abstract

backgroundPrevious thoracic artificial lungs (TALs) had blood flow impedance greater than that of the natural lungs, which could cause abnormal pulmonary hemodynamics. New compliant TALs (cTALs), however, have an impedance lower than that of the natural lung.

methodsIn this study, a cTAL of new design was attached between the pulmonary artery (PA) and the left atrium (LA) in 5 sheep (60.2 ± 1.9 kg). A distal PA band was placed to control the percentage of cardiac output (CO) routed to the cTAL. Rest and exercise conditions were simulated using a continuous dobutamine infusion of 0 and 5 μg/kg/min, respectively. At each dose, a hemodynamic data set was acquired at baseline (no flow to the cTAL), and 60%, 75%, and 90% of CO was shunted to the cTAL.

resultsDevice resistance did not vary with blood flow rate, averaging 0.51 ± 0.03 mm Hg/(L/min). Under all conditions, CO was not significantly different from baseline. Pulmonary system impedance increased above baseline only with 5 μg/kg/min of dobutamine and 90% of CO diverted to the cTAL.

conclusionsResults indicated minimal changes in pulmonary hemodynamics during PA-LA cTAL attachment for high device flows under rest and exercise conditions.

Indexed as

Artificial OrgansLungLung ComplianceAnimalsMalePhysical Conditioning, AnimalProsthesis ImplantationRegional Blood FlowRestSheepVascular Resistance

Identifiers

PMID22959566
PMCPMC3606559

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.