Evidence map›Paper›PMID 22945269›Full record

ArticleEuropean journal of applied physiology2013

Inter-unit variability in two ParvoMedics TrueOne 2400 automated metabolic gas analysis systems.

D J Macfarlane, H L Wu

Abstract readComparative StudyEvaluation Study
In one paragraph

Article in European journal of applied physiology, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

20 citing papers in PubMed.

  1. Trial
  2. Article
  3. In-Field Validity and Inter-Unit Variability of Metabolic Carts During Simulated Exercise.Scandinavian journal of medicine & science in sports · 2026
    Article
  4. Article
  5. Article
  6. Article
  7. Validity and reproducibility of VOScandinavian journal of medicine & science in sports · 2021
    Article
  8. Article
  9. Article
  10. Observational
  11. Article
  12. Article
  13. Determining the Accuracy and Reliability of Indirect Calorimeters Utilizing the Methanol Combustion Technique.Nutrition in clinical practice : official publication of the American Society for Parenteral and Enteral Nutrition · 2018
    Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

D J MacfarlaneInstitute of Human Performance, The University of Hong Kong, Pokfulam, Hong Kong. djmac@hku.hk
H L Wu

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Knowing the inter-unit variability, especially the technological error, is important when using many physiological measurement systems, yet no such inter-unit analysis has been undertaken on duplicate automated gas analysis systems. This study investigated the inter-unit performance of two identical ParvoMedics TrueOne 2400 automated gas analysis systems during a range of submaximal steady-state exercises performed on an electromagnetic cycle ergometer. Fifteen adult males were tested on two separate days a rest, 30, 60, 90, and 120 Watts with the duplicate gas analysis units arranged (1) collaterally (2 min of steady-state expired gas was alternately passed through each system), and (2) simultaneously (identical steady-state expired gas was passed simultaneously through both systems). Total within-subject variation (biological + technological) was determined from the collateral tests, but the unique inter-unit variability (technological error between identical systems) was shown by the simultaneous tests. Absolute percentage errors (APE), coefficient of variations (CV), effect sizes and Bland-Altman analyses were undertaken on the metabolic data, including expired ventilation (V (E)), oxygen consumption (VO(2)) and carbon dioxide production (VCO(2)). The few statistically significant differences detected between the two duplicate systems were determined to have small or trivial effect sizes, and their magnitudes to be of little physiological importance. The total within-subject variations for VO(2), VCO(2) and V (E) each equated to a mean CV and mean APE value of ~4 and ~6 %, whilst the respective inter-unit technological errors equated to ~1.5 and ~2.1 %. The two ParvoMedics TrueOne 2400 systems demonstrated excellent inter-unit agreement.

Indexed as

Exercise TestPulmonary Gas ExchangeAdultBreath TestsCarbon DioxideElectronic Data ProcessingGasesHumansMaleModels, BiologicalObserver VariationOxygenSpirometryYoung AdultCarbon DioxideGasesOxygen

Identifiers

PMID22945269
PMCPMC3569593

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.