Evidence map›Paper›PMID 22935171›Full record

ArticleVirology journal2012

Two types of nanoparticle-based bio-barcode amplification assays to detect HIV-1 p24 antigen.

Huahuang Dong, Jianli Liu, Hong Zhu, Chin-Yih Ou, Wenge Xing, Maofeng Qiu, Guiyun Zhang, Yao Xiao, Jun Yao, Pinliang Pan and 1 more

Open access · goldAbstract readEvaluation Study
In one paragraph

Article in Virology journal, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
0.9field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 31 citations in OpenAlex.

  1. Rapid diagnosis of COVID-19RSC advances · 2022
    Review
  2. Micro and Nanoscale Technologies for Diagnosis of Viral Infections.Small (Weinheim an der Bergstrasse, Germany) · 2021
    Review
  3. Review
  4. Review
  5. A Spellbinding Interplay Between Biological Barcoding and Nanotechnology.Frontiers in bioengineering and biotechnology · 2020
    Review
  6. Review
  7. Review
  8. Review
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 2 institutions in 2 countries.

Huahuang DongNational HIV/HCV Reference Laboratory, National Center for AIDS/STD Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing, The People's Republic of China.
Jianli Liu
Hong Zhu
Chin-Yih Ou
Wenge Xing
Maofeng Qiu
Guiyun Zhang
Yao Xiao
Jun Yao
Pinliang Pan
Yan Jiang
Chinese Center For Disease Control and Prevention · CNCenters for Disease Control and Prevention · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundHIV-1 p24 antigen is a major viral component of human immunodeficiency virus type 1 (HIV-1) which can be used to identify persons in the early stage of infection and transmission of HIV-1 from infected mothers to infants. The detection of p24 is usually accomplished by using an enzyme-linked immunosorbent assay (ELISA) with low detection sensitivity. Here we report the use of two bio-barcode amplification (BCA) assays combined with polymerase chain reaction (PCR) and gel electrophoresis to quantify HIV-1 p24 antigen.

methodA pair of anti-p24 monoclonal antibodies (mAbs) were used in BCA assays to capture HIV-1 p24 antigen in a sandwich format and allowed for the quantitative measurement of captured p24 using PCR and gel electrophoresis. The first 1 G12 mAb was coated on microplate wells or magnetic microparticles (MMPs) to capture free p24 antigens. Captured p24 in turn captured 1D4 mAb coated gold nanoparticle probes (GNPs) containing double-stranded DNA oligonucleotides. One strand of the oligonucleotides was covalently immobilized whereas the unbound complimentary bio-barcode DNA strand could be released upon heating. The released bio-barcode DNA was amplified by PCR, electrophoresed in agarose gel and quantified.

resultsThe in-house ELISA assay was found to quantify p24 antigen with a limit of detection (LOD) of 1,000 pg/ml and a linear range between 3,000 and 100,000 pg/ml. In contrast, the BCA-based microplate method yielded an LOD of 1 pg/ml and a linear detection range from 1 to 10,000 pg/ml. The BCA-based MMP method yielded an LOD of 0.1 pg/ml and a linear detection range from 0.1 to 1,000 pg/ml.

conclusionsWhen combined with PCR and simple gel electrophoresis, BCA-based microplate and MMPs assays can be used to quantify HIV-1 p24 antigen. These methods are 3-4 orders of magnitude more sensitive than our in-house ELISA-based assay and may provide a useful approach to detect p24 in patients newly infected with HIV.

Indexed as

NanoparticlesAntibodies, MonoclonalElectrophoresis, Agar GelHIV-1HIV AntibodiesHIV Core Protein p24HIV InfectionsHumansMolecular Diagnostic TechniquesNucleic Acid Amplification TechniquesSensitivity and SpecificityVirologyAntibodies, MonoclonalHIV AntibodiesHIV Core Protein p24

Identifiers

PMID22935171
PMCPMC3496641
OpenAlexW2121155862

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.