Evidence map›Paper›PMID 22929652›Full record

ArticleUltrasound in medicine & biology2012

Stability of echogenic liposomes as a blood pool ultrasound contrast agent in a physiologic flow phantom.

Kirthi Radhakrishnan, Kevin J Haworth, Shao-Ling Huang, Melvin E Klegerman, David D McPherson, Christy K Holland

Abstract read
In one paragraph

Article in Ultrasound in medicine & biology, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

20 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Review
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Current status and prospects for microbubbles in ultrasound theranostics.Wiley interdisciplinary reviews. Nanomedicine and nanobiotechnology
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Kirthi RadhakrishnanDepartment of Internal Medicine, Division of Cardiovascular Diseases, University of Cincinnati, 231 Albert Sabin Way, Cincinnati, OH 45267-0586, USA. radhakki@mail.uc.edu
Kevin J Haworth
Shao-Ling Huang
Melvin E Klegerman
David D McPherson
Christy K Holland

Funding

Ultrasound-Assisted Thrombolysis for Stroke TherapyR01NS047603 · NINDS · UNIVERSITY OF CINCINNATI · PI HOLLAND, CHRISTY K. · 2004 to 2018
$7.5M
Echogenic Targeted Liposomes:Transfection/Drug DeliveryR01HL074002 · NHLBI · UNIVERSITY OF TEXAS HLTH SCI CTR HOUSTON · PI MCPHERSON, DAVID D · 2004 to 2013
$5.3M
TARGETED LIPOSOMES FOR ACOUSTIC CARDIOVASCULAR IMAGINGR01HL059586 · NHLBI · UNIVERSITY OF TEXAS HLTH SCI CTR HOUSTON · PI MCPHERSON, DAVID D · 1998 to 2012
$3.2M
Passive Cavitation Image-Guided Ultrasound-Mediated Drug Delivery for Atheroma ThF32HL104916 · NHLBI · UNIVERSITY OF CINCINNATI · PI HAWORTH, KEVIN JOSEPH · 2010 to 2011
$103k
NHLBI NIH HHS F32 HL104916NHLBI NIH HHS R01 HL059586NHLBI NIH HHS R01 HL074002NINDS NIH HHS R01 NS047603
6 · The paper itself

Abstract

Echogenic liposomes (ELIP) are multifunctional ultrasound contrast agents (UCAs) with a lipid shell encapsulating both air and an aqueous core. ELIP are being developed for molecular imaging and image-guided therapeutic delivery. Stability of the echogenicity of ELIP in physiologic conditions is crucial to their successful translation to clinical use. In this study, we determined the effects of the surrounding media's dissolved air concentration, temperature transition and hydrodynamic pressure on the echogenicity of a chemically modified formulation of ELIP to promote stability and echogenicity. ELIP samples were diluted in porcine plasma or whole blood and pumped through a pulsatile flow system with adjustable hydrodynamic pressures and temperature. B-mode images were acquired using a clinical diagnostic scanner every 5 s for a total duration of 75 s. Echogenicity in porcine plasma was assessed as a function of total dissolved gas saturation. ELIP were added to plasma at room temperature (22 °C) or body temperature (37 °C) and pumped through a system maintained at 22 °C or 37 °C to study the effect of temperature transitions on ELIP echogenicity. Echogenicity at normotensive (120/80 mmHg) and hypertensive pressures (145/90 mmHg) was measured. ELIP were echogenic in plasma and whole blood at body temperature under normotensive to hypertensive pressures. Warming of samples from room temperature to body temperature did not alter echogenicity. However, in plasma cooled rapidly from body temperature to room temperature or in degassed plasma, ELIP lost echogenicity within 20 s at 120/80 mmHg. The stability of echogenicity of a modified ELIP formulation was determined in vitro at body temperature, physiologic gas concentration and throughout the physiologic pressure range. However, proper care should be taken to ensure that ELIP are not cooled rapidly from body temperature to room temperature as they will lose their echogenic properties. Further in vivo investigations will be needed to evaluate the optimal usage of ELIP as blood pool contrast agents.

Indexed as

BloodContrast MediaHumansLiposomesPhantoms, ImagingRheologyUltrasonographyContrast MediaLiposomes

Identifiers

PMID22929652
PMCPMC4919816

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.