ArticleJournal of the American Society for Mass Spectrometry2012
Advanced mass calibration and visualization for FT-ICR mass spectrometry imaging.
Article in Journal of the American Society for Mass Spectrometry, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
16 citing papers in PubMed, 44 citations in OpenAlex.
- UHRMS Formula Assignment: Diophantine-Based Recalibration Yields Lorentzian Mass Error Distribution as the Limiting Factor.Journal of the American Society for Mass Spectrometry · 2026Article
- Fellgett Revisited: On the Nature of Noise in Two-Dimensional Mass Spectrometry.Journal of the American Society for Mass Spectrometry · 2024Article
- External Data Systems Enable Enhanced (and Sustainable) Fourier Transform Mass Spectrometry Imaging for Legacy Hybrid Linear Ion Trap-Orbitrap Platforms.Journal of the American Society for Mass Spectrometry · 2024Article
- [Application advances of mass spectrometry imaging technology in environmental pollutants analysis and their toxicity research].Se pu = Chinese journal of chromatography · 2024Review
- Ion-to-Image, i2i, a Mass Spectrometry Imaging Data Analysis Platform for Continuous Ionization Techniques.Analytical chemistry · 2023Article
- FT-ICR Mass Spectrometry Imaging at Extreme Mass Resolving Power Using a Dynamically Harmonized ICR Cell with 1ω or 2ω Detection.Analytical chemistry · 2022Article
- ADVANCES IN HIGH-RESOLUTION MALDI MASS SPECTROMETRY FOR NEUROBIOLOGY.Mass spectrometry reviews · 2022Review
- Unsupervised machine learning for exploratory data analysis in imaging mass spectrometry.Mass spectrometry reviews · 2020Review
- Ultra-High Mass Resolving Power, Mass Accuracy, and Dynamic Range MALDI Mass Spectrometry Imaging by 21-T FT-ICR MS.Analytical chemistry · 2020Article
- Increased throughput and ultra-high mass resolution in DESI FT-ICR MS imaging through new-generation external data acquisition system and advanced data processing approaches.Scientific reports · 2019Article
- Cyclotron Phase-Coherent Ion Spatial Dispersion in a Non-Quadratic Trapping Potential is Responsible for FT-ICR MS at the Cyclotron Frequency.Journal of the American Society for Mass Spectrometry · 2018Article
- Fourier Transform Ion Cyclotron Resonance Mass Spectrometry at the Cyclotron Frequency.Journal of the American Society for Mass Spectrometry · 2017Article
- Mass recalibration of FT-ICR mass spectrometry imaging data using the average frequency shift of ambient ions.Journal of the American Society for Mass Spectrometry · 2013Article
- MSiReader: an open-source interface to view and analyze high resolving power MS imaging files on Matlab platform.Journal of the American Society for Mass Spectrometry · 2013Article
- Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) imaging source coupled to a FT-ICR mass spectrometer.Journal of the American Society for Mass Spectrometry · 2013Article
- Advances in mass spectrometry imaging for spatial cancer metabolomics.Mass spectrometry reviewsReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Mass spectrometry imaging by Fourier transform ion cyclotron resonance (FT-ICR) yields hundreds of unique peaks, many of which cannot be resolved by lower performance mass spectrometers. The high mass accuracy and high mass resolving power allow confident identification of small molecules and lipids directly from biological tissue sections. Here, calibration strategies for FT-ICR MS imaging were investigated. Sub-parts-per-million mass accuracy is demonstrated over an entire tissue section. Ion abundance fluctuations are corrected by addition of total and relative ion abundances for a root-mean-square error of 0.158 ppm on 16,764 peaks. A new approach for visualization of FT-ICR MS imaging data at high resolution is presented. The "Mosaic Datacube" provides a flexible means to visualize the entire mass range at a mass spectral bin width of 0.001 Da. The high resolution Mosaic Datacube resolves spectral features not visible at lower bin widths, while retaining the high mass accuracy from the calibration methods discussed.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.