Evidence map›Paper›PMID 22879927›Full record

ArticlePloS one2012

Achieving maximal speed of solution exchange for patch clamp experiments.

Jerónimo Auzmendi, Darío Fernández Do Porto, Carla Pallavicini, Luciano Moffatt

Abstract read
In one paragraph

Article in PloS one, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Jerónimo AuzmendiInstituto de Química Física de los Materiales Medio Ambiente y Energía, Facultad de Ciencias Exactas y Naturales, Universidad de Buenos Aires, Buenos Aires, Argentina.
Darío Fernández Do Porto
Carla Pallavicini
Luciano Moffatt

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundResolving the kinetics of agonist binding events separately from the subsequent channel gating processes requires the ability of applying and removing the agonist before channel gating occurs. No reported system has yet achieved pulses shorter than 100 µs, necessary to study nicotinic ACh receptor or AMPA receptor activation. METHODOLOGY/PRINCIPAL

findingsSolution exchange systems deliver short agonist pulses by moving a sharp interface between a control and an experimental solution across a channel preparation. We achieved shorter pulses by means of an exchange system that combines a faster flow velocity, narrower partition between the two streams, and increased velocity and bandwidth of the movement of the interface. The measured response of the entire system was fed back to optimize the voltage signal applied to the piezoelectric actuator overcoming the spurious oscillations arising from the mechanical resonances when a high bandwidth driving function was applied. Optimization was accomplished by analyzing the transfer function of the solution exchange system. When driven by optimized command pulses the enhanced system provided pulses lasting 26 ± 1 µs and exchanging 93 ± 1% of the solution, as measured in the open tip of a patch pipette. CONCLUSIONS/SIGNIFICANCE: Pulses of this duration open the experimental study of the molecular events that occur between the agonist binding and the opening of the channel.

Indexed as

ElectricityMovementPatch-Clamp TechniquesRheologySolutionsTime FactorsSolutions

Identifiers

PMID22879927
PMCPMC3411769

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked