ArticleProceedings of SPIE--the International Society for Optical Engineering2012
Dose reduction by moving a region of interest (ROI) beam attenuator to follow a moving object of interest.
Article in Proceedings of SPIE--the International Society for Optical Engineering, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 3 citations in OpenAlex.
- A Patient Dose-Reduction Technique for Neuroendovascular Image-Guided Interventions: Image-Quality Comparison Study.AJNR. American journal of neuroradiology · 2018Article
- Dynamic electronic collimation method for 3-D catheter tracking on a scanning-beam digital x-ray system.Journal of medical imaging (Bellingham, Wash.) · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
Abstract
Region-of-interest (ROI) fluoroscopy takes advantage of the fact that most neurovascular interventional activity is performed in only a small portion of an x-ray imaging field of view (FOV). The ROI beam filter is an attenuating material that reduces patient dose in the area peripheral to the object of interest. This project explores a method of moving the beam-attenuator aperture with the object of interest such that it always remains in the ROI. In this study, the ROI attenuator, which reduces the dose by 80% in the peripheral region, is mounted on a linear stage placed near the x-ray tube. Fluoroscopy is performed using the Microangiographic Fluoroscope (MAF) which is a high-resolution, CCD-based x-ray detector. A stainless-steel stent is selected as the object of interest, and is moved across the FOV and localized using an object-detection algorithm available in the IMAQ Vision package of LabVIEW. The ROI is moved to follow the stent motion. The pixel intensities are equalized in both FOV regions and an adaptive temporal filter dependent on the motion of the object of interest is implemented inside the ROI. With a temporal filter weight of 5% for the current image in the peripheral region, the SNR measured is 47.8. The weights inside the ROI vary between 10% and 33% with a measured SNR of 57.9 and 35.3 when the object is stationary and moving, respectively. This method allows patient dose reduction as well as maintenance of superior image quality in the ROI while tracking the object.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.