Evidence map›Paper›PMID 22855510›Full record

ArticleJournal of clinical microbiology2012

Prospective evaluation of a matrix-assisted laser desorption ionization-time of flight mass spectrometry system in a hospital clinical microbiology laboratory for identification of bacteria and yeasts: a bench-by-bench study for assessing the impact on time to identification and cost-effectiveness.

K E Tan, B C Ellis, R Lee, P D Stamper, S X Zhang, K C Carroll

Open access · bronzeAbstract readComparative StudyEvaluation Study
In one paragraph

Article in Journal of clinical microbiology, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 124 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
124citing papers in PubMed, 1 pooled it
24.3field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

124 citing papers in PubMed, 1 synthesis or guideline pooled it, 319 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Diagnostic test accuracy of an automated device for the MALDI target preparation for microbial identification.European journal of clinical microbiology & infectious diseases : official publication of the European Society of Clinical Microbiology · 2023
    Article
  17. Review
  18. Review
  19. Review
  20. Article

64 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

K E TanJohns Hopkins University School of Medicine, Baltimore, MD, USA.
B C Ellis
R Lee
P D Stamper
S X Zhang
K C Carroll
Johns Hopkins Hospital · USJohns Hopkins University · USJohns Hopkins Medicine · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has been found to be an accurate, rapid, and inexpensive method for the identification of bacteria and yeasts. Previous evaluations have compared the accuracy, time to identification, and costs of the MALDI-TOF MS method against standard identification systems or commercial panels. In this prospective study, we compared a protocol incorporating MALDI-TOF MS (MALDI protocol) with the current standard identification protocols (standard protocol) to determine the performance in actual practice using a specimen-based, bench-by-bench approach. The potential impact on time to identification (TTI) and costs had MALDI-TOF MS been the first-line identification method was quantitated. The MALDI protocol includes supplementary tests, notably for Streptococcus pneumoniae and Shigella, and indications for repeat MALDI-TOF MS attempts, often not measured in previous studies. A total of 952 isolates (824 bacterial isolates and 128 yeast isolates) recovered from 2,214 specimens were assessed using the MALDI protocol. Compared with standard protocols, the MALDI protocol provided identifications 1.45 days earlier on average (P < 0.001). In our laboratory, we anticipate that the incorporation of the MALDI protocol can reduce reagent and labor costs of identification by $102,424 or 56.9% within 12 months. The model included the fixed annual costs of the MALDI-TOF MS, such as the cost of protein standards and instrument maintenance, and the annual prevalence of organisms encountered in our laboratory. This comprehensive cost analysis model can be generalized to other moderate- to high-volume laboratories.

Indexed as

BacteriaBacterial InfectionsCost-Benefit AnalysisFungiHumansMicrobiological TechniquesMolecular Diagnostic TechniquesMycosesSpectrometry, Mass, Matrix-Assisted Laser Desorption-IonizationTime Factors

Identifiers

PMID22855510
PMCPMC3457442
OpenAlexW2167477904

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.