Evidence map›Paper›PMID 22848436›Full record

ArticlePloS one2012

Molecular and microscopic analysis of bacteria and viruses in exhaled breath collected using a simple impaction and condensing method.

Zhenqiang Xu, Fangxia Shen, Xiaoguang Li, Yan Wu, Qi Chen, Xu Jie, Maosheng Yao

Abstract read
In one paragraph

Article in PloS one, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers.

0numbers the graph read from it
0cells of the map it votes in
19citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

19 citing papers in PubMed.

  1. Review
  2. Review
  3. Observational
  4. Article
  5. Micro and Nanoscale Technologies for Diagnosis of Viral Infections.Small (Weinheim an der Bergstrasse, Germany) · 2021
    Review
  6. Observational
  7. Article
  8. On airborne transmission and control of SARS-Cov-2.The Science of the total environment · 2020
    Article
  9. Perspectives in lung microbiome research.Current opinion in microbiology · 2020
    Review
  10. Review
  11. Review
  12. Article
  13. Article
  14. Review
  15. Microbiota in Exhaled Breath Condensate and the Lung.Applied and environmental microbiology · 2017
    Article
  16. Article
  17. Article
  18. Chinese science bulletin = Kexue tongbao · 2014
    Article
  19. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Zhenqiang XuState Key Joint Laboratory of Environmental Simulation and Pollution Control, College of Environmental Sciences and Engineering, Peking University, Beijing, China.
Fangxia Shen
Xiaoguang Li
Yan Wu
Qi Chen
Xu Jie
Maosheng Yao

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Exhaled breath condensate (EBC) is increasingly being used as a non-invasive method for disease diagnosis and environmental exposure assessment. By using hydrophobic surface, ice, and droplet scavenging, a simple impaction and condensing based collection method is reported here. Human subjects were recruited to exhale toward the device for 1, 2, 3, and 4 min. The exhaled breath quickly formed into tiny droplets on the hydrophobic surface, which were subsequently scavenged into a 10 µL rolling deionized water droplet. The collected EBC was further analyzed using culturing, DNA stain, Scanning Electron Microscope (SEM), polymerase chain reaction (PCR) and colorimetry (VITEK 2) for bacteria and viruses.Experimental data revealed that bacteria and viruses in EBC can be rapidly collected using the method developed here, with an observed efficiency of 100 µL EBC within 1 min. Culturing, DNA stain, SEM, and qPCR methods all detected high bacterial concentrations up to 7000 CFU/m(3) in exhaled breath, including both viable and dead cells of various types. Sphingomonas paucimobilis and Kocuria variants were found dominant in EBC samples using VITEK 2 system. SEM images revealed that most bacteria in exhaled breath are detected in the size range of 0.5-1.0 µm, which is able to enable them to remain airborne for a longer time, thus presenting a risk for airborne transmission of potential diseases. Using qPCR, influenza A H3N2 viruses were also detected in one EBC sample. Different from other devices restricted solely to condensation, the developed method can be easily achieved both by impaction and condensation in a laboratory and could impact current practice of EBC collection. Nonetheless, the reported work is a proof-of-concept demonstration, and its performance in non-invasive disease diagnosis such as bacterimia and virus infections needs to be further validated including effects of its influencing matrix.

Indexed as

ExhalationGram-Negative Bacterial InfectionsInfluenza A Virus, H3N2 SubtypeInfluenza, HumanSphingomonasHumansMicroscopy, Electron, ScanningPolymerase Chain Reaction

Identifiers

PMID22848436
PMCPMC3405091

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.