ArticleThe Journal of thoracic and cardiovascular surgery2013
Bioengineered human and allogeneic pulmonary valve conduits chronically implanted orthotopically in baboons: hemodynamic performance and immunologic consequences.
Article in The Journal of thoracic and cardiovascular surgery, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 1 synthesis or guideline pooled it, 28 citations in OpenAlex.
- Pooled it
- Advances in xenogeneic donor decellularized organs: A review on studies with sheep and porcine-derived heart valves.Bioengineering & translational medicine · 2024Review
- Characterization of a Decellularized Sheep Pulmonary Heart Valves and Analysis of Their Capability as a Xenograft Initial Matrix Material in Heart Valve Tissue Engineering.Bioengineering (Basel, Switzerland) · 2023Article
- Calcification in Pulmonary Heart Valve Tissue Engineering: A Systematic Review and Meta-Analysis of Large-Animal Studies.JACC. Basic to translational science · 2023Review
- Tissue Engineered Transcatheter Pulmonary Valved Stent Implantation: Current State and Future Prospect.International journal of molecular sciences · 2022Review
- Can Heart Valve Decellularization Be Standardized? A Review of the Parameters Used for the Quality Control of Decellularization Processes.Frontiers in bioengineering and biotechnology · 2022Review
- Next-generation tissue-engineered heart valves with repair, remodelling and regeneration capacity.Nature reviews. Cardiology · 2021Review
- The Potential Impact and Timeline of Engineering on Congenital Interventions.Pediatric cardiology · 2020Review
- Can We Grow Valves Inside the Heart? Perspective on Material-based In Situ Heart Valve Tissue Engineering.Frontiers in cardiovascular medicine · 2018Article
- CD133 antibody conjugation to decellularized human heart valves intended for circulating cell capture.Biomedical materials (Bristol, England) · 2015Article
- Early systemic cellular immune response in children and young adults receiving decellularized fresh allografts for pulmonary valve replacement.Tissue engineering. Part A · 2014Article
- Transesophageal Echocardiography in Healthy Young Adult Male Baboons (Progress in pediatric cardiology · 2013Article
- Recellularization of decellularized heart valves: Progress toward the tissue-engineered heart valve.Journal of tissue engineeringReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 2 institutions in 1 country.
Funding
Abstract
objectiveThis study assesses in a baboon model the hemodynamics and human leukocyte antigen immunogenicity of chronically implanted bioengineered (decellularized with collagen conditioning treatments) human and baboon heart valve scaffolds.
methodsFourteen baboons underwent pulmonary valve replacement, 8 with decellularized and conditioned (bioengineered) pulmonary valves derived from allogeneic (N = 3) or xenogeneic (human) (N = 5) hearts; for comparison, 6 baboons received clinically relevant reference cryopreserved or porcine valved conduits. Panel-reactive serum antibodies (human leukocyte antigen class I and II), complement fixing antibodies (C1q binding), and C-reactive protein titers were measured serially until elective sacrifice at 10 or 26 weeks. Serial transesophageal echocardiograms measured valve function and geometry. Differences were analyzed with Kruskal-Wallis and Wilcoxon rank-sum tests.
resultsAll animals survived and thrived, exhibiting excellent immediate implanted valve function by transesophageal echocardiograms. Over time, reference valves developed a smaller effective orifice area index (median, 0.84 cm(2)/m(2); range, 1.22 cm(2)/m(2)), whereas all bioengineered valves remained normal (effective orifice area index median, 2.45 cm(2)/m(2); range, 1.35 cm(2)/m(2); P = .005). None of the bioengineered valves developed elevated peak transvalvular gradients: 5.5 (6.0) mm Hg versus 12.5 (23.0) mm Hg (P = .003). Cryopreserved valves provoked the most intense antibody responses. Two of 5 human bioengineered and 2 of 3 baboon bioengineered valves did not provoke any class I antibodies. Bioengineered human (but not baboon) scaffolds provoked class II antibodies. C1q(+) antibodies developed in 4 recipients.
conclusionsValve dysfunction correlated with markers for more intense inflammatory provocation. The tested bioengineering methods reduced antigenicity of both human and baboon valves. Bioengineered replacement valves from both species were hemodynamically equivalent to native valves.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.