ArticleJournal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research2012
Microarchitecture and bone quality in the human calcaneus: local variations of fabric anisotropy.
Article in Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 24 citations in OpenAlex.
- Multiscale Femoral Neck Imaging and Multimodal Trabeculae Quality Characterization in an Osteoporotic Bone Sample.Materials (Basel, Switzerland) · 2022Article
- Gait speed and spasticity are independently associated with estimated failure load in the distal tibia after stroke: an HR-pQCT study.Osteoporosis international : a journal established as result of cooperation between the European Foundation for Osteoporosis and the National Osteoporosis Foundation of the USA · 2022Article
- Local and global microarchitecture is associated with different features of bone biomechanics.Bone reports · 2020Article
- Article
- Human cochlear hydrodynamics: A high-resolution μCT-based finite element study.Journal of biomechanics · 2017Article
- Changes of elastic constants and anisotropy patterns in trabecular bone during disuse-induced bone loss assessed by poroelastic ultrasound.Journal of biomechanical engineering · 2015Article
- Dynamic permeability of the lacunar-canalicular system in human cortical bone.Biomechanics and modeling in mechanobiology · 2014Article
- Effect of maternal care on hearing onset induced by developmental changes in the auditory periphery.The Journal of neuroscience : the official journal of the Society for Neuroscience · 2014Article
- Clinical assessment of the 1/3 radius using a new desktop ultrasonic bone densitometer.Ultrasound in medicine & biology · 2013Article
- A symmetry invariant formulation of the relationship between the elasticity tensor and the fabric tensor.Mechanics of materials : an international journal · 2012Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
Abstract
The local variability of microarchitecture of human trabecular calcaneus bone is investigated using high-resolution micro-computed tomography (µCT) scanning. The fabric tensor is employed as the measure of the microarchitecture of the pore structure of a porous medium. It is hypothesized that a fabric tensor-dependent poroelastic ultrasound approach will more effectively predict the data variance than will porosity alone. The specific aims of the present study are as follows: (1) to quantify the morphology and local anisotropy of the calcaneus microarchitecture with respect to anatomical directions; (2) to determine the interdependence, or lack thereof, of microarchitecture parameters, fabric, and volumetric bone mineral density (vBMD); and (3) to determine the relative ability of vBMD and fabric measurements in evaluating the variance in ultrasound wave velocity measurements along orthogonal directions in the human calcaneus. Our results show that the microarchitecture in the analyzed regions of human calcanei is anisotropic, with a preferred alignment along the posterior-anterior direction. Strong correlation was found between most scalar architectural parameters and vBMD. However, no statistical correlation was found between vBMD and the fabric components, the measures of the pore microstructure orientation. Therefore, among the parameters usually considered for cancellous bone (ie, classic histomorphometric parameters such as porosity, trabecular thickness, number and separation), only fabric components explain the data variance that cannot be explained by vBMD, a global mass measurement, which lacks the sensitivity and selectivity to distinguish osteoporotic from healthy subjects because it is insensitive to directional changes in bone architecture. This study demonstrates that a multidirectional, fabric-dependent poroelastic ultrasound approach has the capability of characterizing anisotropic bone properties (bone quality) beyond bone mass, and could help to better understand anisotropic changes in bone architecture using ultrasound.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.