Evidence map›Paper›PMID 22805356›Full record

ArticleCardiovascular ultrasound2012

Effects of ultrasound and ultrasound contrast agent on vascular tissue.

Steven C Wood, Sible Antony, Ronald P Brown, Jin Chen, Edward A Gordon, Victoria M Hitchins, Qin Zhang, Yunbo Liu, Subha Maruvada, Gerald R Harris

Open access · goldAbstract readComparative Study
In one paragraph

Article in Cardiovascular ultrasound, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
0.8field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it, 11 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Contrast Ultrasound Imaging Does Not Affect Heat Shock Protein 70 Expression in Cholesterol-Fed Rabbit Aorta.Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2015
    Article
  4. Contrast Ultrasound Imaging of the Aorta Does Not Affect Progression of Atherosclerosis or Cardiovascular Biomarkers in ApoE-/- Mice.Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2015
    Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 3 institutions in 1 country.

Steven C WoodFood and Drug Administration, Center for Devices and Radiological Health (CDRH), 10903 New Hampshire Avenue, Silver Spring, MD 20993, USA. steven.wood@fda.hhs.gov
Sible Antony
Ronald P Brown
Jin Chen
Edward A Gordon
Victoria M Hitchins
Qin Zhang
Yunbo Liu
Subha Maruvada
Gerald R Harris
Center for Devices and Radiological Health · USCenter for Drug Evaluation and Research · USGeorge Washington University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundUltrasound (US) imaging can be enhanced using gas-filled microbubble contrast agents. Strong echo signals are induced at the tissue-gas interface following microbubble collapse. Applications include assessment of ventricular function and virtual histology.

aimWhile ultrasound and US contrast agents are widely used, their impact on the physiological response of vascular tissue to vasoactive agents has not been investigated in detail. METHODS AND

resultsIn the present study, rat dorsal aortas were treated with US via a clinical imaging transducer in the presence or absence of the US contrast agent, Optison. Aortas treated with both US and Optison were unable to contract in response to phenylephrine or to relax in the presence of acetylcholine. Histology of the arteries was unremarkable. When the treated aortas were stained for endothelial markers, a distinct loss of endothelium was observed. Importantly, terminal deoxynucleotidyl transferase mediated dUTP nick-end-labeling (TUNEL) staining of treated aortas demonstrated incipient apoptosis in the endothelium.

conclusionsTaken together, these ex vivo results suggest that the combination of US and Optison may alter arterial integrity and promote vascular injury; however, the in vivo interaction of Optison and ultrasound remains an open question.

Indexed as

Ultrasonography, Doppler, PulsedAnimalsAorta, ThoracicApoptosisContrast MediaDisease Models, AnimalIn Situ Nick-End LabelingMaleRatsRats, Sprague-DawleyVasoconstrictionContrast Media

Identifiers

PMID22805356
PMCPMC3493263
OpenAlexW2110824572

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.