Reproducibility of planar (123)I-meta-iodobenzylguanidine (MIBG) myocardial scintigraphy in patients with heart failure.

Caroline E Veltman, Mark J Boogers, Joris E Meinardi, Imad Al Younis, Petra Dibbets-Schneider, Ernst E Van der Wall, Jeroen J Bax, Arthur J H A Scholte

Abstract read
In one paragraph

Article in European journal of nuclear medicine and molecular imaging, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 32 papers.

0numbers the graph read from it
0cells of the map it votes in
32citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

32 citing papers in PubMed.

  1. Relationship of left ventricular global longitudinal strain with cardiac autonomic denervation as assessed byJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2019
    Trial
  2. Trial
  3. Value of multi-parameterEJNMMI research · 2025
    Article
  4. Review
  5. Machine learning-based prediction of conversion coefficients for I-123 metaiodobenzylguanidine heart-to-mediastinum ratio.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2023
    Article
  6. Article
  7. Article
  8. Serial changes in cardiac sympathetic nervous function after transcatheter aortic valve replacement: A prospective observational study usingJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2022
    Observational
  9. Article
  10. TheJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2021
    Article
  11. Quality and utility of [Annals of nuclear medicine · 2021
    Article
  12. How to best appreciate the possible clinical role of cardiacJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2021
    Article
  13. Cardio-pulmonary involvement in pulmonary arterial hypertension: A perfusion and innervation scintigraphic evaluation.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2021
    Article
  14. Article
  15. Observational
  16. Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2019
    Article
  17. Reliability of theJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2019
    Article
  18. Role of cardiacJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2019
    Observational
  19. IsAnnals of nuclear medicine · 2018
    Article
  20. Influence of ROI definition on the heart-to-mediastinum ratio in planarJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2018
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Caroline E VeltmanDepartment of Cardiology, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, The Netherlands. c.e.veltman@lumc.nl
Mark J Boogers
Joris E Meinardi
Imad Al Younis
Petra Dibbets-Schneider
Ernst E Van der Wall
Jeroen J Bax
Arthur J H A Scholte

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeDespite its high prognostic value, widespread clinical implementation of (123)I-meta-iodobenzylguanidine (MIBG) myocardial scintigraphy is hampered by a lack of validation and standardization. The purpose of this study was to assess the reliability of planar (123)I-MIBG myocardial scintigraphy in patients with heart failure (HF).

methodsPlanar myocardial MIBG images of 70 HF patients were analysed by two experienced and one inexperienced observer. The reproducibility of early and delayed heart-to-mediastinum (H/M) ratios, as well as washout rate (WR) calculated by two different methods, was assessed using the intraclass correlation coefficient (ICC) and the Bland-Altman analysis. In addition, a subanalysis in patients with a very low H/M ratio (delayed H/M ratio <1.4) was performed. The delayed H/M ratio was also assessed using fixed-size oval and circular cardiac regions of interest (ROI).

resultsIntra- and interobserver analyses and experienced versus inexperienced observer analysis showed excellent agreement for the measured early and delayed H/M ratios and WR on planar (123)I-MIBG images (the ICCs for the delayed H/M ratios were 0.98, 0.96 and 0.90, respectively). In addition, the WR without background correction resulted in higher reliability than the WR with background correction (the interobserver Bland-Altman 95 % limits of agreement were -2.50 to 2.16 and -10.10 to 10.14, respectively). Furthermore, the delayed H/M ratio measurements remained reliable in a subgroup of patients with a very low delayed H/M ratio (ICC 0.93 for the inter-observer analysis). Moreover, a fixed-size cardiac ROI could be used for the assessment of delayed H/M ratios, with good reliability of the measurement.

conclusionThe present study showed a high reliability of planar (123)I-MIBG myocardial scintigraphy in HF patients, confirming that MIBG myocardial scintigraphy can be implemented easily for clinical risk stratification in HF.

Indexed as

3-IodobenzylguanidineRadiopharmaceuticalsAgedCardiac-Gated Single-Photon Emission Computer-Assisted TomographyFemaleHeart FailureHumansMaleMyocardial Perfusion ImagingPrognosisReproducibility of Results3-IodobenzylguanidineRadiopharmaceuticals

Identifiers

PMID22790878
PMCPMC3458210

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.