Evidence map›Paper›PMID 22772733›Full record

ArticleMedical & biological engineering & computing2012

Robotic palpation and mechanical property characterization for abnormal tissue localization.

Bummo Ahn, Yeongjin Kim, Cheol Kyu Oh, Jung Kim

Abstract read
PubMed Publisher
In one paragraph

Article in Medical & biological engineering & computing, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed
3.3field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed, 58 citations in OpenAlex.

  1. Article
  2. Review
  3. A Minimally Invasive Robotic Tissue Palpation Device.IEEE transactions on bio-medical engineering · 2024
    Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 2 countries.

Bummo AhnThe Simulation Group, Department of Radiology, Center for Integration of Medicine and Innovative Technology, Harvard Medical School,Cambridge, MA 02139, USA.
Yeongjin Kim
Cheol Kyu Oh
Jung Kim
Korea Advanced Institute of Science and Technology · KRHarvard University · USInje University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Palpation is an intuitive examination procedure in which the kinesthetic and tactile sensations of the physician are used. Although it has been widely used to detect and localize diseased tissues in many clinical fields, the procedure is subjective and dependent on the experience of the individual physician. Palpation results and biomechanics-based mechanical property characterization are possible solutions that can enable the acquisition of objective and quantitative information on abnormal tissue localization during diagnosis and surgery. This paper presents an integrated approach for robotic palpation combined with biomechanical soft tissue characterization. In particular, we propose a new palpation method that is inspired by the actual finger motions that occur during palpation procedures. To validate the proposed method, robotic palpation experiments on silicone soft tissue phantoms with embedded hard inclusions were performed and the force responses of the phantoms were measured using a robotic palpation system. Furthermore, we carried out a numerical analysis, simulating the experiments and estimating the objective and quantitative properties of the tissues. The results indicate that the proposed approach can differentiate diseased tissue from normal tissue and can characterize the mechanical information of diseased tissue, which means that this method can be applied as a means of abnormality localization to diagnose prostate cancers.

Indexed as

Models, BiologicalAnimalsDiagnosis, Computer-AssistedEquipment DesignEquipment Failure AnalysisHardness TestsHumansPalpationPhysical StimulationRobotics

Identifiers

PMID22772733
OpenAlexW1966418027

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.