Evidence map›Paper›PMID 22766669›Full record

ArticleAJNR. American journal of neuroradiology2013

Spinal cord hypothermia without systemic hypothermia.

P D Purdy, R L Novakovic, B P Giles, S L Miller, M S Riegel

2 registry-linked trialsOpen access · hybridAbstract read
In one paragraph

Article in AJNR. American journal of neuroradiology, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.4field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT06375278 narecruitingnot on this mapstarted 2024, after this paper: background citation

Device to Deliver Intra-Operative Therapeutic Hypothermia for Hearing Preservation in Cochlear Implantation

TypeinterventionalSponsorRestorear Devices LLCRan2024 to 2027Enrolled54ConditionsCochlear Implants, Cochlear Implantation, Hearing LossArmsIntra-Ear Canal Cooling Catheter
NCT06729632 narecruitingnot on this mapstarted 2024, after this paper: background citation

Non-Invasive System to Deliver Therapeutic Hypothermia for Protection Against Noise-Induced Hearing Loss

TypeinterventionalSponsorRestorear Devices LLCRan2024 to 2027Enrolled116ConditionsNoise Exposure, Noise-induced Hearing Loss, Noise, Adverse EffectArmsCold pack-delivered mild therapeutic hypothermia
3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 9 citations in OpenAlex.

  1. Review
  2. Article
  3. Anatomical Correlates and Surgical Considerations for Localized Therapeutic Hypothermia Application in Cochlear Implantation Surgery.Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology · 2019
    Article
  4. Observational
  5. Article
  6. Cold and hot.AJNR. American journal of neuroradiology · 2014
    Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

P D PurdyDepartment of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas, USA. phillip.purdy@utsouthwestern.edu
R L Novakovic
B P Giles
S L Miller
M S Riegel
Foundation Center · USSouthwestern Medical Center · USThe University of Texas Southwestern Medical Center · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background and purposeHypothermia has been shown to be beneficial in the setting of acute SCI. However, widespread use has been hindered by the need for systemic hypothermia as the vehicle for achieving spinal cord hypothermia. This study demonstrates that localized spinal cord hypothermia can be achieved via a percutaneous approach while maintaining systemic normothermia. MATERIALS AND

methodsFive Yucatan swine underwent catheterization of the subarachnoid space and infusion of room temperature, chilled, and iced PL solutions into the cervical spinal canal, with drainage from the lumbar canal. Thermocouples were placed within the spinal cord and in the subarachnoid space and recorded during infusions and recovery from hypothermia.

resultsResults demonstrated that hypothermia as low as 16.8°C is feasible in the spinal cord with retention of systemic normothermia, with strong (r = 0.95) correlation between the spinal cord temperature and the CSF temperature. Degrees of cooling varied with flow rates and with infusate temperature.

conclusionsWhile the data are preliminary in a small group of animals, the ability to rapidly create a wide range of controlled spinal cord hypothermia while preserving normal body temperature warrants wider exploration. The study also indicates that further investigation of the hypothesis that CSF temperature monitoring may be an acceptable surrogate for direct spinal cord temperature monitoring should be pursued.

Indexed as

AnimalsBody TemperatureHypothermia, InducedSpinal CordSwine

Identifiers

PMID22766669
PMCPMC7966333
OpenAlexW2329915319

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.