Evidence map›Paper›PMID 22763499›Full record

ArticleSleep & breathing = Schlaf & Atmung2013

CPAP interface: satisfaction and side effects.

Adel Bachour, Pirjo Vitikainen, Paula Virkkula, Paula Maasilta

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in Sleep & breathing = Schlaf & Atmung, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

20 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Treatment of Adult Obstructive Sleep Apnea With Positive Airway Pressure: An American Academy of Sleep Medicine Systematic Review, Meta-Analysis, and GRADE Assessment.Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine · 2019
    Pooled it
  3. Trial
  4. Observational
  5. Observational
  6. Article
  7. Article
  8. Observational
  9. Development of a smart-fit system for CPAP interface selection.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2021
    Article
  10. Review
  11. Article
  12. Article
  13. Review
  14. Article
  15. Article
  16. Effect of addition of chin strap on PAP compliance, nightly duration of use, and other factors.Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine · 2014
    Article
  17. Article
  18. Article
  19. Article
  20. Impact of the type of mask on the effectiveness of and adherence to continuous positive airway pressure treatment for obstructive sleep apnea.Jornal brasileiro de pneumologia : publicacao oficial da Sociedade Brasileira de Pneumologia e Tisilogia
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Adel BachourSleep Unit, Pulmonary Department, Helsinki University Hospital, P.O. Box 160, Helsinki 00029, Finland. adel.bachour@hus.fi
Pirjo Vitikainen
Paula Virkkula
Paula Maasilta

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study aimed to evaluate the care receiver's satisfaction with the continuous positive airway pressure (CPAP) interfaces.

methodsA questionnaire with visual analog scales was sent to all our CPAP patients (0 = absolutely unsatisfied, 100 = very satisfied). From the ResMed ResScan program, we obtained the CPAP daily use and air leak values.

resultsWe received 730 answers (70 % of participants); females comprised 22 %. A total of 391 patients had ResMed interfaces, 227 had Respironics, 87 had Fisher & Paykel (F&P), and 25 patients had other interfaces. Interfaces were nasal for 79 %, nasal pillows for 9 %, oronasal for 9 %, and unidentified for 3 % of cases. The mean ± SD satisfaction rate was 68 ± 25. No statistically significant differences were found regarding the type or brand of interface, previous interface experience, or the age or gender of the patient. Users of ResMed interfaces had significantly (p < 0.01) fewer cases of disturbing leaks than did users of Respironics or F&P interfaces (60 vs. 70 and 72 %, respectively). The ResMed Ultra Mirage interface had the fewest cases of disturbing leaks. Values for the measured median leaks were a mean of 5.9 ± 7.2 l/min, and those for the maximum leaks were 39.3 ± 22.2 l/min with no differences between brands. The users of F&P interfaces experienced significantly (p < 0.01) more comfort and used the CPAP device significantly (p < 0.007) more than did users of ResMed or Respironics interfaces (88 % of cases vs. 65 and 57 % and 6.2 ± 2.6 vs. 5.3 ± 2.8 or 5.8 ± 2.8 h/day, respectively).

conclusionsThe majority of patients consider the use of the CPAP interface disturbing even though the satisfaction rate is good with no differences between brands.

Indexed as

Patient SatisfactionAdultAgedAged, 80 and overContinuous Positive Airway PressureEquipment DesignEquipment FailureFemaleHumansMaleMiddle AgedPatient ComplianceSleep Apnea, ObstructiveSurveys and QuestionnairesYoung Adult

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.