ArticleThe Journal of hospital infection2012
Fast-track ventilation strategy to cater for pandemic patient isolation surges.
Article in The Journal of hospital infection, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 22 citations in OpenAlex.
- Development and optimization of disinfection protocol for negative pressure wards: a Delphi study.BMC infectious diseases · 2025Article
- Reducing the risk of viral contamination during the coronavirus pandemic by using a protective curtain in the operating room.Patient safety in surgery · 2022Article
- Article
- Minimizing the COVID-19 spread in hospitals through optimization of ventilation systems.Physics of fluids (Woodbury, N.Y. : 1994) · 2022Article
- Healthcare-acquired clusters of COVID-19 across multiple wards in a Scottish health board.The Journal of hospital infection · 2022Article
- Infection prevention and control considerations regarding ventilation in acute hospitals.Infection prevention in practice · 2021Article
- Reducing the risk of COVID-19 transmission in hospitals: focus on additional infection control strategies.Surgery (Oxford, Oxfordshire) · 2021Review
- Engineering Solutions for Preventing Airborne Transmission in Hospitals with Resource Limitation and Demand Surge.Indian journal of critical care medicine : peer-reviewed, official publication of Indian Society of Critical Care Medicine · 2021Review
- Development of positive/negative pressure booth generating airflow for protection of medical staff from contagious respiratory pathogens.Journal of thoracic disease · 2020Article
- New applications of a portable isolation hood for use in several settings and as a clean hood.Journal of thoracic disease · 2020Article
- Modelling levels of nitrous oxide exposure for healthcare professionals during EMONO usage.Annals of occupational and environmental medicine · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe shortage of isolation facilities in hospitals was highlighted during the severe acute respiratory syndrome (SARS) pandemic in 2003. Yet, as the nature and scale of future pandemics cannot be adequately estimated, it is difficult to justify construction of sufficient isolation facilities. A fast-track and cost-effective ventilation strategy for the retrofitting of existing general wards could help hospitals deal with patient surges.
aimThis article reviews the effectiveness of a fast-track, makeshift isolation approach employed during the SARS outbreak which involved installing simple window-mounted exhaust fans to create negative-pressure airflow in hospital general wards.
methodsComputational fluid dynamics (CFD) was used to assess by simulation whether the approach adopted meets US Centers for Disease and Control and Prevention requirements for properly constructed isolation wards.
findingsCFD simulation revealed that this makeshift approach could match the ventilation standards of isolation rooms. The approach was certainly effective as no secondary infections were reported in hospitals that used it during SARS.
conclusionsWhen there is a shortfall in isolation facilities to accommodate a surge in patients, the proposed ventilation set-up could be quickly and widely implemented by existing general wards.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials