Evidence map›Paper›PMID 22735977›Full record

Trial reportKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2013

Evaluation of the accuracy of a patient-specific instrumentation by navigation.

Fabio Conteduca, Raffaele Iorio, Daniele Mazza, Ludovico Caperna, Gabriele Bolle, Giuseppe Argento, Andrea Ferretti

Abstract readClinical Trial
PubMed Publisher
In one paragraph

Trial report in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 35 papers, 3 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
35citing papers in PubMed, 3 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

35 citing papers in PubMed, 3 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Pooled it
  4. Trial
  5. Trial
  6. Trial
  7. Trial
  8. Trial
  9. Trial
  10. Trial
  11. The radiological outcomes of patient-specific instrumentation versus conventional total knee arthroplasty.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2014
    Trial
  12. Trial
  13. Trial
  14. Article
  15. Article
  16. Article
  17. Article
  18. [Total knee arthroplasty with 3D printing technique versus conventional surgery: comparison of the outcomes].Nan fang yi ke da xue xue bao = Journal of Southern Medical University · 2017
    Article
  19. Observational
  20. Assessment of patient-specific instrumentation precision through bone resection measurements.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2017
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Fabio ConteducaOrthopaedic Unit and "Kirk Kilgour" Sports Injury Centre, S. Andrea Hospital, University of Rome "Sapienza", Via Grottarossa, 1035, Rome, RM, Italy.
Raffaele Iorio
Daniele Mazza
Ludovico Caperna
Gabriele Bolle
Giuseppe Argento
Andrea Ferretti

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe aim of this study is to evaluate the accuracy of a patient-specific instrumentation (PSI) as assessed by the intraoperative use of knee navigation software during the surgical procedure.

methodsFifteen patients with primary gonarthrosis were selected for unilateral total knee arthroplasty. The first three patients were excluded from this study, as they were considered to be a warm up to set-up the procedure. All patients were operated on with a cemented posterior-stabilised prosthesis cruciate ligament-sacrificing by the same surgeon using the patient matched cutting jigs. The size of the implant, level of resection, and alignment in the coronal and sagittal planes were evaluated. An unsatisfactory result was considered an error ≥2° in both planes for each component as a possible error of 4° could result in aggravation.

resultsOn the coronal plane the mean deviation of the tibial guide from the ideal alignment was 1.2 ± 1.5 (range 0-5°) and in the sagittal plane was 3.8 ± 2.4 (range 0-7.5°). On the coronal plane the mean deviation of the femoral guide from the ideal alignment was 1.2 ± 0.6 and in the sagittal was 3.7 ± 2.

conclusionOn the basis of this preliminary experience the PSI system based only on data acquisition with A-P radiograms and RMN cannot be defined as accurate. In cases of the use of the custom made cutting jigs it is recommended to perform an accurate control of the alignment before making the cuts, for any step of the procedure. LEVEL OF EVIDENCE: II.

Indexed as

Knee ProsthesisAgedAged, 80 and overArthroplasty, Replacement, KneeBone MalalignmentFemaleHumansMagnetic Resonance ImagingMaleOsteoarthritis, KneePosterior Cruciate LigamentPostoperative ComplicationsPreoperative CareReproducibility of ResultsSoftwareSurgery, Computer-Assisted

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.