Evidence map›Paper›PMID 22714949›Full record

ArticleJournal of the American Society for Mass Spectrometry2012

Absolute quantification of prion protein (90-231) using stable isotope-labeled chymotryptic peptide standards in a LC-MRM AQUA workflow.

Robert Sturm, Gloria Sheynkman, Clarissa Booth, Lloyd M Smith, Joel A Pedersen, Lingjun Li

Abstract read
In one paragraph

Article in Journal of the American Society for Mass Spectrometry, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.6field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 34 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Robert SturmDepartment of Chemistry, University of Wisconsin, Madison, WI 53705, USA.
Gloria Sheynkman
Clarissa Booth
Lloyd M Smith
Joel A Pedersen
Lingjun Li
University of Wisconsin–Madison · US

Funding

Institutional Training in the Genomic SciencesT32HG002760 · NHGRI · UNIVERSITY OF WISCONSIN-MADISON · PI Qiongshi Lu · 2003 to 2026
$17.7M
Wisconsin Center of Excellence in Genomics ScienceP50HG004952 · NHGRI · TEXAS BIOMEDICAL RESEARCH INSTITUTE · PI OLIVIER, MICHAEL · 2009 to 2013
$13.0M
Clinical Neuroengineering Training ProgramT32EB011434 · NIBIB · UNIVERSITY OF WISCONSIN-MADISON · PI MEYERAND, MARY E., PEARCE, ROBERT A · 2011 to 2015
$869k
NHGRI NIH HHS 1P50HG004952NHGRI NIH HHS 5T32HG002760NHGRI NIH HHS P50 HG004952NHGRI NIH HHS T32 HG002760NIBIB NIH HHS T32 EB011434
6 · The paper itself

Abstract

Substantial evidence indicates that the disease-associated conformer of the prion protein (PrP(TSE)) constitutes the etiologic agent in prion diseases. These diseases affect multiple mammalian species. PrP(TSE) has the ability to convert the conformation of the normal prion protein (PrP(C)) into a β-sheet rich form resistant to proteinase K digestion. Common immunological techniques lack the sensitivity to detect PrP(TSE) at subfemtomole levels, whereas animal bioassays, cell culture, and in vitro conversion assays offer higher sensitivity but lack the high-throughput the immunological assays offer. Mass spectrometry is an attractive alternative to the above assays as it offers high-throughput, direct measurement of a protein's signature peptide, often with subfemtomole sensitivities. Although a liquid chromatography-multiple reaction monitoring (LC-MRM) method has been reported for PrP(TSE), the chemical composition and lack of amino acid sequence conservation of the signature peptide may compromise its accuracy and make it difficult to apply to multiple species. Here, we demonstrate that an alternative protease (chymotrypsin) can produce signature peptides suitable for a LC-MRM absolute quantification (AQUA) experiment. The new method offers several advantages, including: (1) a chymotryptic signature peptide lacking chemically active residues (Cys, Met) that can confound assay accuracy; (2) low attomole limits of detection and quantitation (LOD and LOQ); and (3) a signature peptide retaining the same amino acid sequence across most mammals naturally susceptible to prion infection as well as important laboratory models. To the authors' knowledge, this is the first report on the use of a non-tryptic peptide in a LC-MRM AQUA workflow.

Indexed as

Amino Acid SequenceAnimalsCattleChromatography, LiquidChymotrypsinCricetinaeHumansIsotope LabelingLinear ModelsMass SpectrometryMiceMolecular Sequence DataPeptide FragmentsPrionsReference StandardsSensitivity and SpecificityChymotrypsinPeptide Fragmentsprion protein (90-231)Prions

Identifiers

PMID22714949
PMCPMC3579656
OpenAlexW2123885588

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.