Evidence map›Paper›PMID 22702415›Full record

ArticleAnalytical chemistry2012

A simple, robust orthogonal background correction method for two-dimensional liquid chromatography.

Marcelo R Filgueira, Cecilia B Castells, Peter W Carr

Abstract read
In one paragraph

Article in Analytical chemistry, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Marcelo R FilgueiraDepartment of Chemistry, Smith and Kolthoff Halls, University of Minnesota, 207 Pleasant Street S.E., Minneapolis, Minnesota 55455, USA.
Cecilia B Castells
Peter W Carr

Funding

SURFACE MODIFIED ZIRCONIA IN ANALYTICAL CHROMATOGRAPHYR01GM054585 · NIGMS · UNIVERSITY OF MINNESOTA TWIN CITIES · PI CARR, PETER W · 1996 to 2011
$3.0M
NIGMS NIH HHS GM054585-15NIGMS NIH HHS R01 GM054585
6 · The paper itself

Abstract

Background correction is a very important step that must be performed before peak detection or any quantification procedure. When successful, this step greatly simplifies such procedures and enhances the accuracy of quantification. In the past, much effort has been invested to correct drifting baseline in one-dimensional chromatography. In fast online comprehensive two-dimensional liquid chromatography (LC×LC) coupled with a diode array detector (DAD), the change in the refractive index (RI) of the mobile phase in very fast gradients causes extremely serious baseline disturbances. The method reported here is based on the use of various existing baseline correction methods of one-dimensional (1D) liquid chromatography to correct the two-dimensional (2D) background in LC×LC. When such methods are applied orthogonally to the second dimension ((2)D), background correction is dramatically improved. The method gives an almost zero mean background level and it provides better background correction than does simple subtraction of a blank. Indeed, the method proposed does not require running a blank sample.

Indexed as

Chromatography, LiquidAlgorithmsRefractometry

Identifiers

PMID22702415
PMCPMC3443619

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.